Tuff Spa Startup
Selecting Tuff Spa Site Location
It is important your new spa be installed on a solid, flat, and level surface that is engineered to
carry a load of 75 pounds per square foot. Spas should not be placed near or below electrical or
telephone cables. If there is not a dedicated 120v receptacle within 10’ of your spa, contact a
Licensed Electrician to supply power near the spa. A GFCI Power Cord is supplied with all 120v
applications. For 240v you will need a licensed electrician to run the necessary wiring unless
proper wiring is already at site location.
120v to 240v Conversion
1. Remove the necessary panel and locate the spa control pack
2. Remove the pack cover and locate the 120v electrical wiring. Remove the 3-wire, 120v cord
and connect the 4-wire, 240v hookup (50 amp breaker required)
3. Locate the jumper wire that connects J11 to J32, remove it
4. Locate the DIP Switch bank and move #10 to the OFF position (down)
5. Turn power on
120v Tuff Spa DIP Switch Settings
240v Tuff Spa DIP Switch Settings