102 103
sequential“ – simple sequential pump circuit
The sequential pump circuit is particularly recommended for long tanks, and should be operated with at least 3 pumps,
because otherwise no pump sequence will be clearly identiable. The Turbelle
®
pumps should be arranged in line, in
order to generate a strong wave front with swelling water movement.
In the eld “mode”, click on the “sequential” button.
Set the “sequential” switching time by clicking on 1 to 10 sec.
In the eld “power control“, the pump performance “low power” and “high power” can be set to the same value for every
output (between 20% and 100%) by clicking on the same value. This will also deactivate the wave motion simulation
for each output.