112 113
“food timer“ – operating in feeding mode
By pressing the “food timer“ button on the Multicontroller 7097 the connected pumps will be switched off, the sh can
feed without disturbance. After the feeding break, the device will automatically switch the pumps back on again. This
will ensure that after the feeding the connected pumps will be put into operation again. The “food timer“ will prevent
up to 40% of food entry into the lter system.
This function is adjustable from 1 to 15 minutes in the eld “options“ (1).
When the feeding break is activated, the green LEDs for the pump outputs 1 to 4 on Multicontroller will switch off, and
will illuminate again after the pumps restart.