BATCH FEED MODE
1. Remove the Magnitop plug and load the unit - DO NOT CRAM THE WASTE INTO THE UNIT.
2. Replace the plug in the “DRAIN” position.
3. Turn on the cold tap - a good fl ow is required.
4. Turn the Magnitop plug to the “GRIND” position.
5. When the grinding has fi nished, allow the unit to run for about 10 seconds.
6. Turn the Magnitop plug to the “DRAIN” position and turn off the water.
CONTINOUS FEED MODE
1. With the Magnitube in the “DRAIN” position, turn on the cold tap.
2. Turn the Magnitube to the “GRIND” position and feed waste.
3. When the grinding has fi nished, allow the unit to run for about 10 seconds.
4. Turn the Magnitube to the “DRAIN” position and turn off the water.
What to do if your Disposer Stops Working
An overload switch protects your Westminster. This will turn off the power in the event of a jam,
overloading, or if the unit is left running for a prolonged period.
1. Turn off the power supply.
2. If your unit has a reverse switch, select the centre “OFF” position.
3. Allow the unit to cool for a few minutes.
4. You will fi nd the red reset button on the bottom of the unit, press it fi rmly upwards.
5. Select either “ON” position on the reverse switch if your unit has one.
6. Restore the power supply.
7. Try the unit.
IF THIS FAILS
1. Repeat steps 1 to 3 above.
2. Insert the de-jam key supplied with your unit and turn in both directions until it rotates freely.
3. Remove the de-jam key.
4. Repeat steps 4 to 7 above.
IF THIS FAILS
1. Check that your power supply is not fused and that your air switch or wall switch is working.
2. Contact Tweeny on 01424 751888 for more help.
User Instructions
Westminster model only
14