IP-ACM Ethernet Door Module
Quick Start Guide
VERSION C0
PART NUMBER 8200-1200-02
MARCH 2016
IP-ACM Ethernet Door Module
The IP-ACM module provides connection and management of the access control for two doors through inputs, outputs,
and reader interfaces. Supporting two readers through Power over Ethernet (PoE), the IP-ACM communicates to the
Ultra General Control Module (GCM) over TCP/IP. The IP-ACM module also has AES256 network encryption from the
unit to the GCM. The encryption settings are determined by the GCM configuration. The maximum number of IP-ACM
modules supported per GCM is 32.
Part Number Description
IP-ACM2-MB IP-ACM, 2 Reader, board only
IP-ACM2-EM IP-ACM, 2 Reader in metal enclosure
IP-ACM2-EP
1
IP-ACM, 2 Reader in plastic enclosure
IP-ACM2-CAN IP-ACM metal enclosure without board
IP-ACM2-CAN-P
2
IP-ACM plastic enclosure without board
Table 1:Part numbers and descriptions of IP-ACM and enclosures
Installation Requirements
Ensure the site is ready:
The module installation must be performed by a certified installer and must be installed within the same protected
premise as the controlling GCM.
For a UL-compliant installation, the power supply must be UL Listed to UL 294 and/or UL 603, low voltage Class 2
power limited with appropriate ratings.
All interconnecting devices must be UL Listed, low voltage Class 2 power limited.
The site must be approved and all wiring must comply with UL requirements and other codes, as appropriate.
Installation shall be in accordance with the National Electric Code, ANSI/NFPA 70-1993.
In this installation, the enclosure is mounted directly to a wall or uni-strut using suitable user-supplied hardware.
The anchoring system must be capable of sustaining, a proof load four times that of the assembly. Refer to the
enclosure dimensions for information on the weight of enclosures. This weight does not include the cables.
1
Not UL listed.
2
Not UL listed.
1
Question and Answer IconNeed help?

Do you have a question about the Tyco Security Products Software House IP-ACM2-CAN-P and is the answer not in the manual?

Summary

Installation Requirements

Enclosures

Plastic Enclosure

Details the plastic enclosure, its dimensions, and installation steps for the IP-ACM module.

Metal Enclosure

Describes the metal enclosure, its mounting holes, dimensions, and installation process.

IP-ACM Power and Wiring Requirements

Configuration and Operation

Supervision Wiring

Explains supervised wiring configurations for inputs, reporting status like short, alert, normal, and open.

Environmental Requirements

Specifies the ambient temperature range and indoor use limitations for the IP-ACM module.

Initial Configuration

Covers Normal Operation and Standalone modes for initial IP-ACM setup.

IP-ACM Overview

Provides a summary of the IP-ACM Ethernet door module, referencing its board layout.

Switches and Jumpers

Details the function and configuration of switches and jumpers on the IP-ACM module.

Ports and Connectors

Details the various ports and connectors available on the IP-ACM module.

Inputs

Explains the four supervised inputs and their configuration options.

Readers and Accessory Modules

Lists the UL-supported Wiegand readers, RS-485 RM Bus modules, and accessory modules.

Regulatory Compliance

Canadian Radio Emissions Requirements

States compliance with Canadian radio noise emission limits for digital apparatus.

FCC Digital Device Limitations

Details FCC compliance for radio and television interference, including operational conditions.