DATA SHEET
Input/Output Modules
Features That Make a Difference:
Provides cost-effective expansion of input and output capacity
Compatible with full range of Software House
®
iSTAR and apC
access control panels
Locate modules up to 1,220 m (4,000 ft) away from controllers using
flexible two-wire RS-485 RM bus
Reduces length of sensor and control wiring to save installation
costs
I8 provides eight Class A supervised inputs
R8 provides eight Form C relay outputs
I8-CSI, configurable supervised input model, allows use of existing
input wiring without changing end-of-line (EOL) resistors
Three status LEDs per input (red/yellow/green) and one per output
enable quick diagnostics and troubleshooting
Small, modular size requires minimal panel space
Dedicated tamper input included on each module
Optional UL-listed enclosure available
The Software House I8, R8, and I8-CSI modules provide a
flexible, cost-effective means to expand the input and output
functionality of any iSTAR or apC access controller. Common
applications include alarm monitoring and control and elevator
control.
The I8 input module provides eight Class A supervised inputs.
Three LEDs per input help the installer commission and
troubleshoot each input circuit red if the input is in alarm,
green for normal, and yellow for a supervision error. LEDs may
be turned off via a DIP switch setting.
The I8-CSI module enhances the functionality of the standard
I8 module by supporting numerous supervised circuit types and
EOL resistance values. This allows the I8-CSI to accommodate
existing field wiring without changing EOL resistors. More
than 20 different circuit types are supported. The circuit type
is selected via a bank of DIP switches and applies to all eight
inputs on the I8-CSI.
The R8 output module provides eight Form C dry contact relay
outputs. A red status LED per output shows the state of the
relay.
All modules feature a dedicated input for an external cabinet
tamper switch and mount easily in the Software House RM-CAN
or RM-DCM-CAN enclosure. The modules communicate with
iSTAR or apC controllers via the two-wire RM bus that allows
total wiring distances of up to 1,220 m (4,000 ft). Up to eight I8s
and eight R8s can be connected to each apC, iSTAR eX, and
iSTAR Pro eight-reader model; up to 16 of each module can be
connected to the iSTAR Pro 16-reader model.
The modules are fully compatible with both C•CURE
®
800/8000
and C•CURE 9000.
Question and Answer IconNeed help?

Do you have a question about the Tyco Software House AS0073-001 and is the answer not in the manual?

Tyco Software House AS0073-001 Specifications

General IconGeneral
CategoryI/O Systems
Number of Inputs8
Number of Outputs8
Communication ProtocolRS-485
Housing MaterialPlastic
Protection ClassIP20
Input Voltage12-24V DC

Summary

Input/Output Modules

General Specifications

Provides general specifications, environmental conditions, and regulatory compliance data for the modules.

18 Input Module

Details the 18 input module, featuring eight Class A supervised inputs and diagnostic LEDs.

18-CSI Input Module

Describes the 18-CSI module, offering configurable supervised inputs and EOL resistor compatibility.

R8 Output Module

Outlines the R8 output module, providing eight Form C dry contact relay outputs and status indicators.

Optional Metal Enclosures

Covers optional metal enclosures for module mounting, including tamper switch functionality.

Model Numbers

Lists the specific part numbers for the various input and output modules and associated enclosures.

Wiring Summary

Summarizes wiring requirements, including signal types, cable specifications, and maximum lengths.

Related product manuals