EasyManua.ls Logo

Tyco Visonic SD-304C PG2 - Specifications and Warranty; Appendix: Specifications

Tyco Visonic SD-304C PG2
6 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D-304286 SD-304C PG2 Installation Instructions 5
in a particular installation. If this device does cause such interference, which can be verified by turning the
device off and on, the user is encouraged to eliminate the interference by one or more of the following
measures:
Re-orient or re-locate the receiving antenna.
Increase the distance between the device and the receiver.
Connect the device to an outlet on a circuit different from the one which supplies power to the receiver.
Consult the dealer or an experienced radio/TV technician
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numerique de la classe B est conforme a la norme NMB-003 du Canada.
WARNING!
To comply with FCC and IC RF exposure compliance requirements, the device should be located at a
distance of at least 20 cm from all persons during normal operation. The antennas used for this product must
not be co-located or operated in conjunction with any other antenna or transmitter.
WARNING!
The user is cautioned that changes or modifications to the unit, not expressly approved by Visonic Ltd., could
void the user’s FCC or other authority to operate the equipment.
Wood
Supports
Soft Iron
Opening
Closing
Direction
Opening
Closing
20mm+/-
5mm
15mm+/-
5mm
X
13mm+/-5mm
11mm+/-
5mm
15mm+/-
5mm
13mm+/-
5mm
Y
14mm+/-5mm
12mm+/-
5mm
26mm+/-
5mm
24mm+/-
5mm
Z
26mm+/-5mm
24mm+/-
5mm
W.E.E.E. Product Recycling Declaration
For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are disca rdin g this pro d u ct and n o t
returning it for repair then you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste.
Directive 2012/19/EU Waste Electrical and Electronic Equipment.
APPENDIX: SPECIFICATIONS
Frequency Band (MHz)
Europe and rest of world: 433-434, 868-869 USA: 912-919
Communication Protocol
PowerG
Alarm Input
One auxiliary
Tamper
Front and back
Supervision
Signaling at 4-min. intervals
Tamper Alert
Reported when a tamper event occurs
Power Supply
Type C
Battery type
3 V Lithium CR-123A type battery, Panasonic, Sanyo or GP only.
Battery Life Expectancy
5 years (for typical use) with all sensors enabled
Low Battery Threshold
2.6 V
Current Consumption
20 30 A approx. (150 mA during transmission)
Shock Detection Radius and
Sensitivity Level
Not EN Tested
EN Certified
Plate material
Shock detection
radius
Plate material
Shock
detection
radius
Sensitivity level
Window
4M
Framed glass window
(standard test material
A1)
1M
15
Wood
3.5M
Wooden plate
(Standard test material
A2)
1M
12
Brick/concrete
walls
2.5M
Concrete plate
(Standard test material
A3)
0.5M
4
Operating Temperature
-10C to 55C (14F to 131F)
Storage Temperature
-20C to 60C (-4F to 140F)
Humidity
Average relative humidity of approximate 75% non-condensing. For 30 days per year relative humidity may
vary between 85 % and 95 % non-condensing
Auxiliary Input Cable Length
10m max.
Auxiliary Input EOL Resistor
2.2 K
Dimensions (LxWxD)
118 x 27 x 30 mm (4-5/8 x 1-1/8 x 1-3/16 in.)
Weight (including battery)
130g (4.6 oz)
Figure 5: Axis Definitions

Related product manuals