INSTALLATION AND OPERATING INSTRUCTIONS
4211-861-G 10-12-16 7013545 314 SKSM 211 B
Page 5
DIAGRAM 6
Sensor
Front Element
Middle Element
Back Element
T1 Control
Pad
Heater Models
1712-450-0206 4.5 kW
1712-600-0206 6.0 kW
1712-800-0206 8.0 kW
1 2
3
P1 P2 P3
1 3 5 7 A1
2 4 6 8 A2
X1 X2 X3 X5 X7
X4 X6 X8
X11 X12
H N N H
11 12 13 14 15 16
2 3
Trans-
former
RB-5 PCB
Contactor
High Limit
K6 K3 K8
K2
11 = orange/white
12 = orange
13 = green/white
14 = blue
15 = blue/white
16 = green
11 = 12 VDC
12 = 0 VDC
13 = K6 (Back Element)
14 = K3 (Middle Element)
15 = K8 (Front Element)
16 = K2 (Light)
3 step thermostat
K8 turns off at - 2c of set point
K3 turns off at set point
K6 turns off at +2c of set point
Testing Procedure
Lead 12 to 13
= 0 VDC (relay closed)
= 12 VDC (relay open)
Lead 12 to 14
= 0 VDC (relay closed)
= 12 VDC (relay open)
Lead 12 to 15
= 0 VDC (relay closed)
= 12 VDC (relay open)
Lead 12 to 16
= 0 VDC (relay closed)
= 12 VDC (relay open)
1601-27
Pig Tail
Copper Jumper
Field Wiring
11/10/16354 SKSM 148 F
Note - Heating elements are voltage specific for 208 volts or 240 volts.
1
2
3
4 5
6
GND
Single Phase Wiring Diagram Color Code
L3
Three Phase Connections
GND
1
2 3
4 5
6
L1
L2
Single Phase Connections
1
2 3
4 5
6
L1
L2
GND