Questions and Answers

  • A
    Anthony BarnesAug 12, 2025
    How to troubleshoot a Tylo SENSE COMMERCIAL 10 Heater when the element in the stone compartment doesn't heat up?
    • M
      Matthew WilsonAug 12, 2025
      If the heater element in the stone compartment of your Tylo Heater isn't warming up, first ensure that the temperature settings on the control panel are set correctly for operation in the stone compartment and are higher than the current ambient temperature. Then, check the fuses on the main switchboard, as some of the RB-box/TS-panel fuses may have tripped. Replace or reset them if necessary. If the element still doesn't heat, the heater element itself, the internal RB-box/TS-panel PCB, or the internal temperature cut-out may be faulty, requiring diagnosis and repair by an authorized electrician.
  • R
    ramirezbeverlyAug 19, 2025
    What to do if my Tylo SENSE COMMERCIAL 10 Heater control panel does not light up?
    • C
      Christopher SmithSep 12, 2025
      If your Tylo Heater control panel isn't lighting up, start by checking if the main power switch is turned on. It should be on the RB-box. Also, inspect the fuses on the main switchboard and replace or reset them if necessary. If these steps don't resolve the issue, there may be a loose contact in the cabling between the RB-box and the control panel. Turn off the RB-box main power switch and reconnect each cable or paired cable to the control panel, then switch the RB-box main power switch back on. If the problem persists, further diagnosis by an authorized electrician is needed, as there could be a faulty 12VDC output, a faulty transformer on the PCB in the RB-box, or a faulty control panel.
  • T
    travis16Aug 27, 2025
    Why do the Tylo SENSE COMMERCIAL 10 fuses trip immediately when I turn on the heater?
    • P
      pcoleAug 27, 2025
      If the fuses or ground fault interrupt device on the main switchboard trip as soon as you turn on your Tylo heater, it indicates a potential short-circuit. This could be due to a faulty heater element, lighting connected to and controlled via the RB-box, an insulation fault in the heater element (especially if the heater hasn't been used for a long time), too much water poured on the heater, or another internal heater fault. In any of these cases, do not use the heater. Switch off the main RB-box switchboard trip and disconnect the heater fuses on the main switchboard. An authorized electrician is required to find the fault.
  • K
    Kelly HendersonSep 3, 2025
    What to do if the sauna lights don't turn on in my Tylo SENSE COMMERCIAL 10 Heater?
    • B
      Bradley PerezSep 3, 2025
      If the lights in your sauna do not come on when switched on at the control panel of your Tylo Heater, the first step is to check the internal glass fuse in the RB-box and replace it if it's faulty. Ensure you switch off the main power switch on the RB-box before replacing the fuse. If the lighting is connected via the RB-box, verify the connections with the authorized electrician who performed the installation of the RB-box and lighting. If the issue persists, there may be an internal RB-box PCB fault, which requires an authorized electrician to diagnose.