EasyManua.ls Logo

UEi DL419 - Voltage Measurement Procedures; DC Voltage Measurement Guide; AC Voltage Measurement Guide; Continuity and Resistance Measurement

UEi DL419
2 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CAT III 1000V
CAT IV 600V
DL419
True RMS
600V 1000A
CAT IV
NCV
MAX/
MIN
LRA
Inrush
Zero
DC/
Rel
RANGE
INRUSH
V
O
L
T
A
G
E
D
E
T
E
C
T
O
R
μ
A
A
V
MFD
Features:
NCV
Rel
MAX/
MIN
RANGE
HOLD
DC Low Amps Measurement -Test lead input
Range Resolution Accuracy Overload Protection
400µA 0.1µA
± (1.2% + 3 digits) 2000µA / 600V RMS
2000µA 1µA
AC Low Amps Measurement -Test lead input
Range Resolution Accuracy Overload Protection
400µA 0.1µA ± (2.0% + 5 digits)
2000µA / 600V RMS
2000µA 1µA ± (1.5% + 5 digits)
True RMS: 45Hz to 400Hz (Crest factor < 3 : 1 )
AC/DC Low Amps: < 2000µA
x1 =
x2 =
CAT III 1000V
CAT IV 600V
DL419
True RMS
600V 1000A
CAT IV
NCV
MAX/
MIN
LRA
Inrush
Zero
DC/
Rel
RANGE
INRUSH
V
O
L
T
A
G
E
D
E
T
E
C
T
O
R
μ
A
A
V
MFD
Center wire in guides for best accuracy.
Opposing currents cancel (use line-splitter when necessary).
Features:
NCV
Zero
DC/
Rel
MAX/
MIN
LRA
Inrush
RANGE
HOLD
DC Amps Measurement
Range Resolution Accuracy Overload Protection
40A 0.01A ± (2.5% + 15 digits)
1000V RMS
400A 0.1A ± (1.5% + 8 digits)
1000A 1A ± (1.5% + 8 digits)
AC Amps Measurement
Range Resolution Accuracy Overload Protection
40A 0.01A ± (2.9% + 15 digits)
1000V RMS400A 0.1A ± (1.9% + 8 digits)
1000A 1A ± (1.9% + 8 digits)
True RMS: 45Hz to 400Hz
AC/DC Amps: < 1000A
Single
Conductor
Only
x1 =
x2 =
CAT III 1000V
CAT IV 600V
DL419
True RMS
600V 1000A
CAT IV
NCV
MAX/
MIN
LRA
Inrush
Zero
DC/
Rel
RANGE
INRUSH
V
O
L
T
A
G
E
D
E
T
E
C
T
O
R
μ
A
A
V
MFD
A
Use CAT III rated leads or higher.
Do not attempt to measure more than 1000V.
Keep hands below line when measuring high current levels.
Select AC or DC voltage source.
Features:
NCV
Rel
MAX/
MIN
RANGE
HOLD
DC Voltage Measurement
Range Resolution Accuracy Overload Protection
400mV 0.1mV
± (0.5% + 4 digits)
1000V
4V 1mV
40V 10mV
400V 100mV
1000V 1V ± (0.8% + 10 digits)
AC Voltage Measurement
Range Resolution Accuracy Overload Protection
400mV 0.1mV
± (2.0% + 5 digits) 1000V RMS
4V 1mV
40V 10mV
400V 100mV
1000V 1V
True RMS: 45Hz to 400Hz
AC / DC Voltage: < 1000V
CAT III 1000V
CAT IV 600V
DL419
True RMS
600V 1000A
CAT IV
NCV
MAX/
MIN
LRA
Inrush
Zero
DC/
Rel
RANGE
INRUSH
V
O
L
T
A
G
E
D
E
T
E
C
T
O
R
μ
A
A
V
MFD
x1 =
x2 =
V
Do not measure resistance on a live circuit.
Features:
NCV
Rel
MAX/
MIN
RANGE
HOLD
Range Resolution Accuracy Overload Protection
400Ω 0.1Ω
± (1.0% + 4 digits)
600V RMS
4kΩ 1Ω
40kΩ 10Ω
400kΩ 100Ω
4MΩ 1kΩ
40MΩ 10kΩ
± (2.0% + 4 digits)
Resistance: < 40MΩ
CAT III 1000V
CAT IV 600V
DL419
True RMS
600V 1000A
CAT IV
NCV
MAX/
MIN
LRA
Inrush
Zero
DC/
Rel
RANGE
INRUSH
V
O
L
T
A
G
E
D
E
T
E
C
T
O
R
μ
A
A
V
MFD
x1 =
x2 =
x3 = MFD
x4 =
MFD
Capacitance (MFD)
x1 =
x2 =
x3 = MFD
x4 =
CAT III 1000V
CAT IV 600V
DL419
True RMS
600V 1000A
CAT IV
NCV
MAX/
MIN
LRA
Inrush
Zero
DC/
Rel
RANGE
INRUSH
V
O
L
T
A
G
E
D
E
T
E
C
T
O
R
μ
A
A
V
MFD
MFD
CAT III 1000V
CAT IV 600V
DL419
True RMS
600V 1000A
CAT IV
NCV
MAX/
MIN
LRA
Inrush
Zero
DC/
Rel
RANGE
INRUSH
V
O
L
T
A
G
E
D
E
T
E
C
T
O
R
μ
A
A
V
MFD
Display shows resistance.
Buzzer sounds if less than 40Ω.
Features:
NCV
MAX/
MIN
HOLD
Audible Continuity
Overload Protection Open Circuit Voltage
600V RMS
<
0.44V
Threshold Approx : < 40Ω
Continuity
x1 =
x2 =
x3 = MFD
x4 =
MFD
LRA Inrush
The UEi LRA Inrush is programmed to properly capture the starting current for
compressor motors.
Select AC Amps
Select the range capable of capturing the maximum value
Press and hold LRA Inrush for two seconds – INRUSH will now be shown
on the screen
Activate compressor and read value on the display
Press and hold LRA Inrush for two seconds to exit
CAT III 1000V
CAT IV 600V
DL419
True RMS
600V 1000A
CAT IV
NCV
MAX/
MIN
LRA
Inrush
Zero
DC/
Rel
RANGE
INRUSH
V
O
L
T
A
G
E
D
E
T
E
C
T
O
R
μ
A
A
V
MFD
LRA
Inrush
INRUSH
Features:
NCV
HOLD
Range Resolution Accuracy Overload Protection
40.00nF 0.01nF
± (3.5% + 6 digits) 600V RMS
400.0nF 0.1nF
4.000uF 0.001µF
40.00uF 0.01µF
400.0uF 0.1µF
2000uF 1µF
Diode
GOOD DIODE
CAT III 1000V
CAT IV 600V
DL419
True RMS
600V 1000A
CAT IV
NCV
MAX/
MIN
LRA
Inrush
Zero
DC/
Rel
RANGE
INRUSH
V
O
L
T
A
G
E
D
E
T
E
C
T
O
R
μ
A
A
V
MFD
Forward Bias
Displays approx.
voltage drop
x1 =
x2 =
x3 = MFD
x4 =
Forward voltage drop if forward biased.
“O.L.” if reverse biased.
Features:
NCV
MAX/
MIN
HOLD
Diode Test
Range Open Circuit Voltage Test Current (Typical) Overload Protection
2.0V
<
1.6V DC 0.25mA 600V RMS
BAD DIODE
Open Diode
Displays "OL"
Both directions
'0' Both directions
or
MFD
Reverse Bias
Displays "OL"
CAT III 1000V
CAT IV 600V
DL419
True RMS
600V 1000A
CAT IV
NCV
MAX/
MIN
LRA
Inrush
Zero
DC/
Rel
RANGE
INRUSH
V
O
L
T
A
G
E
D
E
T
E
C
T
O
R
μ
A
A
V
MFD
Press to zero any offset in Volts AC/DC, DC µA, Amps AC/DC.
◊ Used to monitor change from the present displayed value
Required during DC Amp measurement to establish a zero level
DO NOT use Zero DC/Rel mode at voltages greater than 1000V.
Select DC current
Features:
MAX/
MIN
LRA
Inrush
HOLD
Zero DC Amps / Rel
x1 = on
x2 = off
Zero
DC/
Rel
www. .com
information@itm.com1.800.561.8187
All manuals and user guides at all-guides.com

Related product manuals