Use CAT III rated leads or higher.
Do not attempt to measure more than 1000V DC or 750V AC.
• Press for AC Volts
Note: This is the default setting when first powered on.
◊ Press and hold in AC volts for Hz/Duty Cycle
• Press again for DC volts
• High Volt Visible Alert - Any input exceeding 30V (AC or DC) will light
the NVC LED to alert users to potentially dangerous voltage levels
• Press for T1
• Press again for T2
• Press again for T1-T2
• Press and hold to change scale
Features:
NCV
LINK
MAX/
MIN
HOLD
Range Resolution Accuracy Overload Protection
-22°F ~ 14°F
(-30°C ~ -10°C)
0.1°F
(0.1°C)
± (1.0% + 5.4°F)
± (1.0% + 3.0°C)
30V RMS
15°F ~ 752°F
(-9°C ~ 400°C)
0.1°F
(0.1°C)
± (1.0% + 3.6°F)
± (1.0% + 2.0°C)
Sensor: K-Type Thermocouple, sensor accuracy not included
TEMP/ °F °C°
DL429
True RMS
600V 600A
CAT Ill
CATIII
600V
MAX
30V
T
2
T
1
TEMP
INRUSH
BT RF
T
1
-T
2
NCV
MAX/
MIN
LRA Inrush
RANGE
T
e
m
p
/
°
F
°
C
μ
A
V
H
z
/
D
u
t
y
MFD
LINK
T
e
m
p
/
°
F
°
C
When the meter is powered on, the upper display will always show
amperage, or adapter (ADP) output
• Center wire in guides for best accuracy.
• Opposing currents cancel (use line-splitter when necessary).
Keep hands below line when measuring high current levels.
Features:
NCV
LINK
MAX/
MIN
LRA Inrush
RANGE
HOLD
AC Amps Measurement - Jaw input
Range Resolution Accuracy Overload Protection
60A 0.01A ± (2.9% + 15 digits)
600V RMS
600A 0.1A ± (1.9% + 8 digits)
True RMS: 45Hz to 400Hz
* Minimum Current for Clamp Measurement: 0.2A
AC Amps: < 600A
Single
Conductor
Only
DL429
True RMS
600V 600A
CAT Ill
CATIII
600V
MAX
30V
T
2
T
1
TEMP
INRUSH
BT RF
T
1
-T
2
NCV
MAX/
MIN
LRA Inrush
RANGE
T
e
m
p
/
°
F
°
C
μ
A
V
H
z
/
D
u
t
y
MFD
LINK
DL429
True RMS
600V 600A
CAT Ill
CATIII
600V
MAX
30V
T
2
T
1
TEMP
INRUSH
BT RF
T
1
-T
2
NCV
MAX/
MIN
LRA Inrush
RANGE
T
e
m
p
/
°
F
°
C
μ
A
V
H
z
/
D
u
t
y
MFD
LINK
• Press for DC micro amps
Features:
NCV
LINK
MAX/
MIN
LRA Inrush
RANGE
HOLD
DC Low Amps Measurement -Test lead input
Range Resolution Accuracy Overload Protection
600µA 0.1µA
± (1.2% + 3 digits) 2000µA / 600V RMS
2000µA 1µA
DC Low Amps: < 2000uA
DL429
True RMS
600V 600A
CAT Ill
CATIII
600V
MAX
30V
T
2
T
1
TEMP
INRUSH
BT RF
T1-T2
NCV
MAX/
MIN
LRA Inrush
RANGE
T
e
m
p
/
°
F
°
C
μ
A
V
H
z
/
D
u
t
y
MFD
LINK
DL429
True RMS
600V 600A
CAT Ill
CATIII
600V
MAX
30V
T
2
T
1
TEMP
INRUSH
BT RF
T
1
-T
2
NCV
MAX/
MIN
LRA Inrush
RANGE
T
e
m
p
/
°
F
°
C
μ
A
V
H
z
/
D
u
t
y
MFD
LINK
x1 =
Press and hold =
Hz/Duty Cycle
x2 =
V
H
z
/
D
u
t
y
• Forward voltage drop if forward biased.
• “O.L.” if reverse biased.
Features:
NCV
LINK
MAX/
MIN
HOLD
Diode Test
Range Open Circuit Voltage Test Current (Typical) Overload Protection
2.0V
<
1.6V DC 0.25mA 600V RMS
BAD DIODE
Open Diode
Displays "OL"
Both directions
'0' Both directions
(Shorted)
or
Features:
NCV
LINK
MAX/
MIN
LRA Inrush
RANGE
HOLD
DC Voltage Measurement
Range Resolution Accuracy Overload Protection
600mV 0.1mV
± (0.5% + 4 digits)
1000V
6V 1mV
60V 10mV
600V 100mV
1000V 1V ± (0.8% + 10 digits)
AC Voltage Measurement
Range Resolution Accuracy Overload Protection
600mV 0.1mV
± (2.0% + 5 digits) 750V RMS
6V 1mV
60V 10mV
600V 100mV
750V 1V
True RMS: 45Hz to 400Hz
Frequency Measurement
Range Resolution Accuracy Overload Protection
99.99Hz 0.01Hz
± (0.1% + 4 digits) 600V RMS
999.9Hz 0.1Hz
9.999kHz 1Hz
99.99kHz 10Hz
Sensitivity: 1.8V RMS
Duty Cycle Measurement
Range Accuracy Overload Protection
1.0
˜
99.0% ±(0.2% per kHz + 0.1% + 5 digits) 600V RMS
Audible Continuity
• Press for continuity
• Display shows resistance.
• Buzzer sounds if less than 40Ω.
Features:
NCV
LINK
MAX/
MIN
LINK
HOLD
Overload Protection Open Circuit Voltage
600V RMS
<
0.44V
Threshold Approx : < 40Ω
Resistance
• Press again for resistance
• Do not measure resistance on a live circuit.
Features:
NCV
LINK
MAX/
MIN
LRA Inrush
RANGE
HOLD
Range Resolution Accuracy Overload Protection
600Ω 0.1Ω
± (1.0% + 4 digits)
600V RMS
6kΩ 1Ω
60kΩ 10Ω
600kΩ 100Ω
6MΩ 1kΩ
60MΩ 10kΩ
± (2.0% + 4 digits)
Capacitance
• Press again for capacitance
Features:
NCV
LINK
HOLD
Range Resolution Accuracy Overload Protection
60.00nF 0.01nF
± (3.5% + 6 digits) 600V RMS
600.0nF 0.1nF
6.000μF 0.001μF
60.00μF 0.01μF
600.0μF 0.1μF
2000μF 1μF
/ / MFD /
DL429
True RMS
600V 600A
CAT Ill
CATIII
600V
MAX
30V
T
2
T
1
TEMP
INRUSH
BT RF
T
1
-T
2
NCV
MAX/
MIN
LRA Inrush
RANGE
T
e
m
p
/
°
F
°
C
μ
A
V
H
z
/
D
u
t
y
MFD
LINK
x1 =
x2 =
x3 = MFD
x4 =
MF
D
GOOD DIODE
Diode
• Press again for diode test
DL429
True RMS
600V 600A
CAT Ill
CATIII
600V
MAX
30V
T
2
T
1
TEMP
INRUSH
BT RF
T
1
-T
2
NCV
MAX/
MIN
LRA Inrush
RANGE
T
e
m
p
/
°
F
°
C
μ
A
V
H
z
/
D
u
t
y
MFD
LINK
MFD
Forward Bias
Displays approx.
voltage drop
x1 =
x2 =
x3 = MFD
x4 =
Reverse Bias
Displays "OL"
Connecting and Using the App
• Search for App as, “UEi Wireless”
•
Compatible with iPhone
®
4X and up running iOS
®
7 or higher, Galaxy S4
®
,
Nexus 5™, HTC One
®
running Android™ 4.4 or higher.
• To install or search on iPad
®
use "iPhone
®
only" to find App.
• Press "Link" button on meter to activate wireless "BT"
• Open app. Meter will connect automatically.
Menu
• Press “ ” to connect, disconnect, and
access settings.
Settings
• General settings adjust button sound, vibrate
and refresh rate.
Recording settings
• Continuous reading
• Number of samples
• Sampling interval
Record
• Press to start, stop.
• The number of samples will show in real time
Logs
• Press to view
recorded data.
• Press the entry you wish
to view (yyyy-mm-dd
hh:mm:ss)
• Functions are noted
underneath respectively
AMP-AMP (TOP-
BOTTOM) Display
• Press “ “ button for summary
• Press “ “ button for sample data
• Press “ “ button to export data via email in (.CSV .PNG or .JPG)
formats
Graph
• Press “ ” to view trending data
in real time during measurement.
High
Voltage
Alert
Graph
Graph
All manuals and user guides at all-guides.com