PROBLEM CAUSE REMEDY
Dripping from faucets (gravity stainless
steel faucet)
Nicked or wrong stainless steel gravity
piston gasket
Replace stainless steel piston gasket
Faucet piston out of closing position Check for stainless steel piston free
movement. If necessary clean both piston
and bowl housing.
Check for faucet handle free movement, if
necessary replace faucet handle
Bowls faucet rim damaged Replace bowl
Noisy unit Worn impellers Replace impellers
Bent fan blade Re-bent fan blade to correct aligment
Noisy fan or pump motor Replace noisy motor
Magnetic lock decoupling (chattering) Verify planarity of pump motor bracket
Noisy ball bearings (Arctic Compact
series with multiple bowls only)
Replace magnetic pulley assembly
No magnetic slow mixer rotation Defective drive motor Replace drive motor
Magnetic mixer does not rotate freely on
pivot
Clean both mixer and pivot from traces of
product and if necessary lubricate them
with food grade grease
Ice on the evaporator Increase product level into the bowl
Adjust temperature setting
Check thermostats
No mechanic slow mixer rotation Defective drive motor Replace drive motor
Product excessive thicknes