2) Installation of the tank
a) Place the tank on the control handle tube.
b) Use two clamps to attach the tank to the tube of the control handle. Then
install the hole plate and tighten the nuts on the threads of the clamping
bracket.
c) Connect the water pipe to the water outlet connector.
A - Plate with holes
B - Nut
C - Clamping bracket
3) Brush assembly/disassembly
a) Make sure that the device is turned off and disconnected from the power
supply.
b) Turn the engine 90 °, align the brush with the hook and connect them.