5
Tango 0060 11-2019
Adjust Grinder Setting
Fine/Coarse
Re-run and time test drink (Double shot)
18-26 seconds is usually the target time
Adjust grinder ner for longer extraction
Adjust grinder coarser for faster extraction
Repeat test and adjust as needed until extraction is in range
Adjust Grinders for best extraction: Each PM visit
Step 1: Adjust the grinders ne or coarse for best extraction
time. Typically done with the double espresso drink.
Adjust both grinders.
Run a test drink
(Double shot)
Turn counter-clockwise
for ner left (red) grinder.
Turn clockwise
for ner right (green)
grinder.
Adjustments are opposite for each grinder
Step 2: Capture a sample of the dry ground coee.
Weight the sample and enter the amount into the
calibration programming. (2 sample cycles)
Run 2-3 drinks after
each adjustment.
Note coee
ow time
Adjust grinder
ne or coarse
as needed