27.4
Check points of "TURN OVER PREVENTION DEVICE"
1.Please remove the wiring connector of the load cell.
Please measure the resistance between each terminal.
Please confirm whether in the following ranges.
2.If wiring is moved, and resistance changes greatly,
it is a disconnection or a loose connection.
In that case, please exchange four load cells and
the amplifier.
And, please adjust "TURN OVER PREVENTION DEVICE" again.
④
⇔ 348Ω~358Ω ⇔ 260Ω~270Ω
⇔④ 348Ω~358Ω ⇔④ 260Ω~270Ω
⇔④ 260Ω~270Ω ⇔ 260Ω~270Ω
load cell
27 - 4 )