2. How to make an emergency stop
In case of emergency such as that the crane does not stop operation or the engine will not return
to idling speed even if no crane operation has been made, depress the EMERGENCY switch
on the switch panel.
This makes the crane and the engine to stop operation forcibly.
★
When releasing the emergency stop switch, release it while no crane
operation is being carried out.
Releasing the emergency stop switch while operating the crane allows
the crane to make an abrupt movement that is very dangerous.
WARNING
●
How to make an emergency stop
for the crane and reset it
Depress the EMERGENCY stop switch on
the switch panel of crane body.
The switch is held pushed in allowing the
engine to stop operation.
When the switch is held pushed in, the engine
cannot be re-started.
Rotate the emergency stop switch clockwise
in arrow direction to return to its original
state to release the switch.
●Remarks
When the emergency stop is reset by turning theEMERGENCYstop switch clockwise after
the crane has been stopped by depression ofEMERGENCYstop switch, the engine speed may
increase in a moment which is not abnormal.
When the crane is operated with theEMERGENCYstop switch held pushed in,voice message,
Beep.Service remote Service remote control may be issued or the mode indicator lamp
may show incorrect indication.
Do not operate the crane for about 2 seconds after starter switch
has been tuened on.
The crane is carrying out the system diagnosis to prevent incorrect
operation.
The mode indicator lamp is to be fully lit up for 2 seconds during the
system diagnosis.
If the crane is operated during the system diagnosis, voice message
,Beep, Service remote control, Service remote control,sounds and
the crane is turned into inoperable conditions.
In this case, please turn off starter switch. Please operate the crane
after turning on starter switch again and hearing Remote control ready.
After the system diagnosis has been completed, operate the crane
when the voice message Remote control ready, Remote control ready
is heard.
6.1 Inspection before crane operation
Mode indicator lamp
6-1)
Courtesy of Machine.Market