°C
2.10.8 Sanitary sensor (priority 8)
Description:
Sanitary temperature sensor intervention
Possible solution:
verify the sensor operation and its own connections
2.10.9 Heating sensor (priority 9)
Description: Heating temperature sensor intervention
Possible solution: verify the sensor operation and its own connections
2.10.10 Factory parameters (priority 10)
Description:
Factory parameters alteration
Possible solution:
with the access code, reset the 13 factory parameters
2.10.11 Flame control (priority 11)
Description:
Burner control is damaged.
Possible solution:
replace the main PCB.
2.10.12 Lock-out
Description:
Lack of gas or burner ignition not detected
Possible solution:
verify the gas feeding and the correct operation of the ignition electrode
°C
°C
°C
The tool blinks, by pushing the reset push
button no failure codes are displayed.