4-44 1000 Series / Guide to Installation, Troubleshooting, and Maintenance
Table 4-16—Three-Phase Line Reactor Ratings (575 V)
Power
Current
Inductance
3.0%
Impedance
5.0%
Impedance
hp (kW)
A
rms
mH
mH
11/2
2
12.000
20.000
(1.1)
2
4
12.000
22.000
(1.5)
3
4
9.100
12.000
(2.2)
5
8
5.000
7.500
(3.7)
71/2
12
3.100
5.100
(5.5)
10
12
2.500
4.200
(7.5)
15
18
1.500
2.500
(11)
20
25
1.200
2.000
(15)
25
35
1.200
1.700
(18)
30
35
0.800
1.700
(22)
40
45
0.700
1.200
(30)
50
55
0.500
0.850
(37)
60
80
0.400
0.700
(45)
75
80
0.400
0.700
(55)
100
110
0.300
0.450
(75)
125
130
0.200
0.370
(90)
150
160
0.230
0.320
(110)
200
200
0.190
0.240
(150)
250
250
0.150
0.190
(185)
300
320
0.096
0.160
(225)
350
400
0.082
0.140
(262)
400
400
0.082
0.140
(300)
500
500
0.057
0.096
(375)
600
600
0.048
0.080
(450)

Table of Contents