Do you have a question about the Unico IS36G110 and is the answer not in the manual?
Defines the operational temperature ranges for cooling and heating.
Table detailing compatible outdoor and indoor unit size combinations.
Specifies the diameter of liquid and vapor lines for each indoor unit size.
Rules governing refrigerant tubing length and height between components.
Maximum allowed lineset lengths for different system configurations and refrigerant charges.
Table listing the factory refrigerant charge for each outdoor unit model.
Guidance on calculating and adding refrigerant for linesets exceeding pre-charged lengths.
Provides physical dimensions and diagrams for outdoor unit models.
Lists all field-supplied tools and additional materials required for installation.
Specifies electrical power requirements, circuit ampacity, and overcurrent protection.
Provides instructions and diagrams for outdoor unit placement, mounting, and connections.
Details the procedure for collecting all refrigerant gas into the outdoor unit.
Explains the function and operation of narrow and wide tube service valves.
Diagrams showing refrigerant lineset connections for various single, dual, tri, and quad splits.
Diagrams illustrating power and communication wiring for single and multi-split systems.
Instructions for installing SDHV units, wiring control boxes, and connecting thermostats.
Details setting communication channels for remote controllers and indoor units.
Explains how to set refrigerant circuit numbers using DIP switches on indoor units.
Explains how to access and modify advanced system settings via the Special Functions Menu.
Describes indoor unit operation when the outdoor unit is absent or malfunctioning.
Provides detailed wiring diagrams for SDHV indoor unit circuit boards.
Provides detailed wiring diagrams for outdoor unit circuit boards for various models.
Lists spare parts with P/N and descriptions for IS18G050, IS24G065, IS30G080, IS36G110.
Details fuse types, ratings, dimensions, and Unico part numbers for replacement.
Offers guidance on diagnosing and resolving system issues using LED codes and tools.
Defines the operational temperature ranges for cooling and heating.
Table detailing compatible outdoor and indoor unit size combinations.
Specifies the diameter of liquid and vapor lines for each indoor unit size.
Rules governing refrigerant tubing length and height between components.
Maximum allowed lineset lengths for different system configurations and refrigerant charges.
Table listing the factory refrigerant charge for each outdoor unit model.
Guidance on calculating and adding refrigerant for linesets exceeding pre-charged lengths.
Provides physical dimensions and diagrams for outdoor unit models.
Lists all field-supplied tools and additional materials required for installation.
Specifies electrical power requirements, circuit ampacity, and overcurrent protection.
Provides instructions and diagrams for outdoor unit placement, mounting, and connections.
Details the procedure for collecting all refrigerant gas into the outdoor unit.
Explains the function and operation of narrow and wide tube service valves.
Diagrams showing refrigerant lineset connections for various single, dual, tri, and quad splits.
Diagrams illustrating power and communication wiring for single and multi-split systems.
Instructions for installing SDHV units, wiring control boxes, and connecting thermostats.
Details setting communication channels for remote controllers and indoor units.
Explains how to set refrigerant circuit numbers using DIP switches on indoor units.
Explains how to access and modify advanced system settings via the Special Functions Menu.
Describes indoor unit operation when the outdoor unit is absent or malfunctioning.
Provides detailed wiring diagrams for SDHV indoor unit circuit boards.
Provides detailed wiring diagrams for outdoor unit circuit boards for various models.
Lists spare parts with P/N and descriptions for IS18G050, IS24G065, IS30G080, IS36G110.
Details fuse types, ratings, dimensions, and Unico part numbers for replacement.
Offers guidance on diagnosing and resolving system issues using LED codes and tools.
| Phase | 1 |
|---|---|
| Refrigerant | R410A |
| Voltage | 208-230V |
| Power Supply | 60Hz |
| Operating Temperature (Heating) | 5°F to 75°F |