EasyManua.ls Logo

Unico i Series User Manual

Default Icon
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image

Other manuals for Unico i Series

Question and Answer IconNeed help?

Do you have a question about the Unico i Series and is the answer not in the manual?

Unico i Series Specifications

General IconGeneral
BrandUnico
Modeli Series
CategoryHeat Pump
LanguageEnglish

Summary

Installation Checklist

Special Tools Required

Lists tools and materials needed for installation.

Equipment

Checks if indoor and outdoor units match.

Electrical – High Voltage

Covers high voltage electrical connections and requirements.

Electrical – Low Voltage Communication Wiring

Details low voltage communication wiring.

Electrical – Low Voltage Control Wiring

Explains low voltage control wiring connections.

Switches

Covers indoor blower switch settings.

Piping and Refrigerant

Details refrigerant lineset and piping requirements.

Startup

Outlines the startup sequence for the system.

Important Installation and Safety Information

Special Precautions

Key safety steps during installation and removal.

Handling and Transporting Units

Safe practices for moving indoor and outdoor units.

Installation Site Selection

Guidelines for choosing optimal locations for units.

Refrigerant Tubing Connection

Instructions for connecting refrigerant tubing.

Servicing Safety

Essential safety guidelines for maintenance.

Design and Specifications

Operating Limits

Defines the acceptable operating temperature and humidity ranges for the system.

Allowed Matchups

Lists compatible combinations of outdoor and indoor units.

Lineset Sizes

Details the required diameters for liquid and vapor refrigerant lines.

Indoor Unit Location Design Limits

Specifies rules for refrigerant tubing length and height.

Maximum Allowable Lineset Lengths

Outlines maximum lengths for system configurations.

Factory Refrigerant Charge

Lists the pre-charged refrigerant amount for each outdoor unit.

Adding Refrigerant

Provides guidelines for adding refrigerant for longer linesets.

Outdoor Unit Dimensions

IS18G050 Dimensions

Detailed measurements for the IS18G050 outdoor unit.

IS24G065 Dimensions

Detailed measurements for the IS24G065 outdoor unit.

IS30G080 Dimensions

Detailed measurements for the IS30G080 outdoor unit.

IS36G110 Dimensions

Detailed measurements for the IS36G110 outdoor unit.

Installation

Tools and Materials Required

Lists necessary tools, materials, and accessories for installation.

Additional Materials and Power Supply

Details extra required materials and power supply specifications.

Outdoor Unit Installation Steps

Comprehensive guide for installing the outdoor unit, including clearances and connections.

Pump Down Procedure

Steps to collect refrigerant into the outdoor unit before servicing or moving.

Service Valve Instructions

Valve States and Actions

Explains valve positions for factory state, evacuation, and normal operation.

Refrigerant Lineset Connections

Single-Split Connections

Details lineset configurations for single indoor unit setups.

Dual-Split Connections

Details lineset configurations for dual indoor unit setups.

Tri-Split Connections

Details lineset configurations for tri-split indoor unit setups.

Quad-Split Connections

Details lineset configurations for quad indoor unit setups.

System Wiring Diagrams

Single Indoor Unit Wiring

Wiring diagrams for systems with one indoor unit.

Two Indoor Unit Wiring

Wiring diagrams for systems with two indoor units.

Three Indoor Unit Wiring

Wiring diagrams for systems with three indoor units.

Four Indoor Unit Wiring

Wiring diagrams for systems with four indoor units.

SDHV Air Handler Installation and Wiring

iSeries Remote Thermostat Setup

Instructions for installing and configuring the iSeries remote thermostat.

Standard Heat Pump Thermostat Setup

Instructions for installing and configuring a standard heat pump thermostat.

Thermostat Connection Diagrams

Visual guides for connecting iSeries and standard thermostats.

SDHV Blower Thermostat Input Logic

Explains how thermostat signals map to system response.

Airflow Verification

Procedure to verify airflow against outlet requirements.

Condensate Management Wiring

Wiring for float switches and condensate pumps.

Alarm Output Wiring

Instructions for connecting alarm output signals.

Remote System Control Options

Options for remote ON/OFF and zone damper system setup.

MMI Board LED Status Codes

Explains the meaning of status LEDs on the MMI board.

iSeries Heating Options

Supplemental Heat

Allows heat pump to run simultaneously with backup heat.

Auto Changeover Heat

Switches to backup heat below a set outdoor temperature.

iSeries Heating Comparison

Compares supplemental vs. auto changeover heating methods.

Supplemental Heat (Electric)

Details electric heater connection and sizing.

Supplemental Heat (Hydronic)

Details hydronic coil connection and boiler control.

Automatic Changeover Configuration

Details for hydronic and electric backup in auto changeover.

Indoor Unit and Remote Control Switch Settings

Model Selection via DIP Switches

How to select the SDHV model size using SW1 switches.

Communications Channel Setup

Remote Controller Settings

How to set the channel on the remote controller.

Wall Mount Unit Settings

How to set the channel on wall mount indoor units.

SDHV Fan Coil Unit Settings

How to set the channel on SDHV fan coil indoor units.

Refrigerant Circuit Number Configuration

DIP Switch Method for Circuit Numbering

Using DIP switches to set refrigerant circuit numbers.

Operation

Special Functions Menu (SFM) Overview

Lists available functions and settings accessible via the SFM.

Editing SFM Setpoints

Step-by-step guide on how to navigate and change SFM settings.

Transmitting SFM Codes and Values

Procedures for sending SFM codes and their associated values.

SFM Code Reference

Details for specific SFM codes including setpoint ranges and formulas.

Independent Fan-Coil Operation

How the unit operates without an outdoor unit or with errors.

Service

SDHV Unit Circuit Boards and Wiring Diagrams

Explains the circuit boards and wiring for SDHV units.

Outdoor Unit Circuit Boards and Wiring Diagrams

IS18G050 Outdoor Unit Diagrams

Wiring diagrams and circuit board layouts for the IS18G050 model.

IS24G065 Outdoor Unit Diagrams

Wiring diagrams and circuit board layouts for the IS24G065 model.

Refrigerant Circuiting

IS18G050 Refrigerant Circuit

Diagram showing the refrigerant flow for the IS18G050 model.

IS24G065 Refrigerant Circuit

Diagram showing the refrigerant flow for the IS24G065 model.

IS30G080 Refrigerant Circuit

Diagram showing the refrigerant flow for the IS30G080 model.

IS36G110 Refrigerant Circuit

Diagram showing the refrigerant flow for the IS36G110 model.

Replacement Fuses

Fuse Identification and Specifications

Lists fuse types, ratings, dimensions, and part numbers.

Troubleshooting

iSeries Service Logger Usage

How to use the logger for diagnostics and data collection.

Checking for Software Upgrades

Procedure to check for and apply firmware updates.

Refrigerant Pressure Checks

How to check high and suction side refrigerant pressures.

Defrost Function Adjustment

How to adjust or disable the defrost algorithm.

LED Codes

MMI Board and IR Receiver LED Indicators

Explains LED codes for normal and abnormal behavior on MMI/IR receiver.

Outdoor Unit LED Indicators

Explains LED codes for normal and abnormal behavior on the outdoor unit.