EasyManua.ls Logo

unimom OPERA - Battery, Cycle, and Vacuum Data; Battery Status and Operating Times; Vacuum and Cycle Settings

unimom OPERA
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 |
*
The dierence between OPERA and OPERA eco is that the OPERA has a echargeable battery while the OPERA eco doesn'
t.
The following battery information is only applicable to the OPERA model.
BATTERY, CYCLE AND VACUUM INFORMATION
BATTERY STATUS
1
1
2
3
4
5
2
3
4
5
6
7
8
26
60
Cycle/min
Level
45
60
90
120
150
45
60
90
120
150
45
60
90
120
150
45
60
90
120
150
45
60
90
120
150
45
60
90
120
150
45
60
90
120
150
45
60
90
120
150
45
60
90
120
150
45
60
90
120
150
2 hours 1.5 hours
3 hours
1 hour
70 80 90 100
30 34 38 42
Massage - Single L mode (suction in mmHg) Massage - Single R mode (suction in mmHg)
2 BAR
20 minutes
1 BAR
Less than 5 Minutes
NO BAR
4 BAR
(FULLY CHARGED)
3 BAR
Operating time remaining (approx.)
Charging Time (approx.)
1
2
3
4
5
60
Level
70 80 90 100
1
2
3
4
5
60
Level
(45,45)
(60,60)
(90,90)
(120,120)
(150,150)
(45,45)
(60,60)
(90,90)
(120,120)
(150,150)
(45,45)
(60,60)
(90,90)
(120,120)
(150,150)
(45,45)
(60,60)
(90,90)
(120,120)
(150,150)
(45,45)
(60,60)
(90,90)
(120,120)
(150,150)
(45,45)
(60,60)
(90,90)
(120,120)
(150,150)
(45,45)
(60,60)
(90,90)
(120,120)
(150,150)
(45,45)
(60,60)
(90,90)
(120,120)
(150,150)
(45,45)
(60,60)
(90,90)
(120,120)
(150,150)
(45,45)
(60,60)
(90,90)
(120,120)
(150,150)
90
140
170
200
230
250
270
280
90
140
170
200
230
250
270
280
90
140
170
200
230
250
270
280
90
140
170
200
230
250
270
280
90
140
170
200
230
250
270
280
90
140
170
200
230
250
270
280
90
140
170
200
230
250
270
280
90
140
170
200
230
250
270
280
90
140
170
200
230
250
270
280
90
140
170
200
230
250
270
280
70 80 90 100
Massage – Synchronous mode (suction in mmHg) Massage – Alternate mode (suction in mmHg)
1
2
3
4
5
60
Level
70 80 90 100
Expression – Single L mode (suction in mmHg) Expression – Single R mode (suction in mmHg)
Level
1
2
3
4
5
6
7
8
26 30 34 38 42
Level
1
2
3
4
5
6
7
8
26 30 34 38 42
(90, 90)
(140,140)
(170,170)
(200,200)
(230,230)
(250,250)
(270,270)
(280,280)
(90, 90)
(140,140)
(170,170)
(200,200)
(230,230)
(250,250)
(270,270)
(280,280)
(90, 90)
(140,140)
(170,170)
(200,200)
(230,230)
(250,250)
(270,270)
(280,280)
(90, 90)
(140,140)
(170,170)
(200,200)
(230,230)
(250,250)
(270,270)
(280,280)
(90, 90)
(140,140)
(170,170)
(200,200)
(230,230)
(250,250)
(270,270)
(280,280)
(90, 90)
(140,140)
(170,170)
(200,200)
(230,230)
(250,250)
(270,270)
(280,280)
(90, 90)
(140,140)
(170,170)
(200,200)
(230,230)
(250,250)
(270,270)
(280,280)
(90, 90)
(140,140)
(170,170)
(200,200)
(230,230)
(250,250)
(270,270)
(280,280)
(90, 90)
(140,140)
(170,170)
(200,200)
(230,230)
(250,250)
(270,270)
(280,280)
(90, 90)
(140,140)
(170,170)
(200,200)
(230,230)
(250,250)
(270,270)
(280,280)
Expression – Synchronous mode (suction in mmHg) Expression – Alternate mode (suction in mmHg)
Level
1
2
3
4
5
6
7
8
26 30 34 38 42
Level
Cycle/min
Cycle/min
Cycle/min
Cycle/min
Cycle/min
Cycle/min
Cycle/min

Related product manuals