UNIPULSE F701-C 文技术手册 无锡波贸公司 0510-82706452/13861775500
· Function Selection 功能选择
When using the F701
-
C for any balance weight to undergo type approval by the Measurement
Law, set the 1/4 scale division display to
If it is set to OFF, the "zero point" lights only at a
OFF.
true zero point (0±1/4 scale division).
F701-C 规检时,1/4 分度显示
时,
零点显示点(0±1/4 分度)
·Gravitational Acceleration (Area number input) 度(入)
016
(For details, please refer to "4-4-7" on P.46.) 46 4-4-7
·Gravitational Acceleration (Acceleration input) 度(入)
(9.700~9.999)
(For details, please refer to "4-4-7" on P.46.) 46 4-4-7
Subdisplay selection 辅助显示
5: Near Zero / 近零
Upper Limit /
Lower Limit 下限
4: Final / Over / Under //不足
3: Accumulation Count /
Latest Accumulation Data /
Final 次累计值/重值
2: Latest Accumulation Data /次累计值
Accumulation Value 总累计值
1: Accumulation Count /
Accumulation Value 总累计值
0: None 无辅助显示
(For details, please refer to
"5
-
2" on P.54.)
54 5-2
Display frequency 显示频率
3: 25 times/sec. 25 /
2: 13 times/sec. 13
1: 6 times/sec. 6
0: 3 times/sec. 3
(For details, please refer to "5
-
1" on P.53.)
53 5-1
Request 记事
Unit 单位
5: :N 4: lb
3: kg 千克 2: g
1: t
0: None 无显示
(For details, please refer to
"
4
-
4
-
2" on P.44.)
44 4-4-2
1/4 scale division display1/4 分度
1: ON
0: OFF
(For details, please refer to
"
4
-
4
-
8" on P.48.)
48 4-4-8
Decimal place
3: 0.000 3
2: 0.00
2
1: 0.0 1
0:
0
(For details, please refer to
"
4
-
4
-
3" on P.44.)
44 4-4-3
- 32 -