13
To Convert and/or Adjust
1. Convertible Pressure Regulator
The inlet pressure of the gas supply shall be in accordance with the nominal inlet
pressure of the regulator used on the range or 1/2 psig maximum. The range should
be tested by pressurizing the regulator with an inlet pressure at least 1 inch water
column above the manufacturer's specified manifold pressure shown on the serial
plate. The range will be equipped with one of the two types of regulators shown.