FIRST TIME CONTROL SETUP
SECTION B, PAGE 15
B11. INITIATION MODES: The display now shows:
Press and the display will show:
B11.1 HOLDING INITIATION: When the control is in this mode, if the
foot or hand initiation switch is opened before the start of the first heat cycle,
the electrodes will open and the sequence will stop.
This is the safest mode and should be used if you do not have the Unitrol
SOFT TOUCH safety system installed on this welder, or if you have a light
curtain properly installed to protect the operator from pinch point injury during a
weld sequence.
Even if you have the Unitrol SOFT TOUCH system installed or have a properly
installed light curtain system, leaving the control in the HOLDING INITIATION
mode will allow the operator to open the electrodes before the start of the weld
if the position of the electrode is not correct.
B11.2 MOMENTARY INITIATION: When the control is in this mode,
once the foot or hand initiation switch has been pushed, the sequence will
continue to completion even if the initiation switch has been opened.
YES
Be sure that you set this INITIATION MODE
properly as shown on the next page to prevent
injury to the welder operator.
990-CHOOSE MODE
Of INITIATION:
MOMENTARY or HOLDING
SELECT=YES, SKIP=NO
HOLDING INITIATION
Want to change? Push
The YES or NO button