FIRST TIME CONTROL SETUP
SECTION B, PAGE 24
If you told the control that there were more than 1 TRANSFORMER TAP
SWITCHES, the display will show:
10. Move the metal to another spot a few inches away from the first location.
11. Close the initiation foot switch or hand switches and KEEP THEM CLOSED.
The electrodes will close on the metal and the display will show:
The SOLUTIONi control will make a series of pulses and then display:
12. This sequence will continue until the control has done a LEARN CURVE for all
TAP SWITCHES.
Set TRANSF.TAP to #2
Place metal between
ELECTRODES and then
Close INITIATION SW.
Set TRANSF.TAP to #2
Keep INIT. SW closed
Reading LINE VOLTAGE
MEMORIZING DATA
S W
Open INIT. SWITCH
Welding in CONSTANT CURRENT mode is useful where metal will be
put into and out of the throat of the welder. It will keep the welding
current constant for all metal positions.
Welding in CONSTANT VOLTAGE mode is recommended for all
projection welding (weld nuts, sheets with projections, etc.)