SECTION C, PAGE 10
SOLUTION PERSONALIZATION
C6.1: CLOSE ON FAULT. The
relay will close when an out-of-range
weld has just been completed.
Push to keep the control in this mode.
If you want to change the mode, press
C6.2: CLOSE ON ACCEPTED WELD.
The display will show: The relay will close
when all values being monitored are within
the proper range.
C7 EHR and FAULT RELAY CLOSING TIME: The EHR/FAULT
closing time can be adjusted to keep it closed long enough to allow a PLC or other
control system to recognize the closure.
To adjust this time, press:
The display will show:
If you want to change the default 30 cycles (1/2 second), press and the
display will show:
Enter the desired time (in cycles1/60th second) for the relay to remain closed.
Then push
NOTE: If the initiation is closed during this RELAY ON TIME, the relay will
immediately open and the next weld will start.
FAULT RELAY CLOSES
FOR REJECTED WELD
Want to change? Push
the YES or NO button
YES
NO
FAULT RELAY CLOSES
FOR ACCEPTED WELD
PROGRAM
1
2
9
8
7
EHR/FLT.RELAY ON =30
Want to change? Push
The YES or NO button
YES
EHR/FLT.RELAY ON =30
After entering data
press “YES”
YES
STEP
ENTER