SECTION C, PAGE 15
SOLUTION PERSONALIZATION
If you are in this mode, a new line will appear in all welding programs:
In this mode, the solenoid valve connected to SV1 turns on first to bring the
electrodes closed under low advance fluid force. After the INTENSIF. DELAY
time, the solenoid valve connected to SV0 turns on to put full welding force on the
electrodes.
Push and the display will show the rest of the choices:
C10.3 CLAMP DELAY: Press 4 and the display will show:
Push to use this mode. This is useful for operations that need to clamp a
part first before bringing the welding electrode down.
Push and the display will show:
INTENSIF. DELAY 00
00CY
BLOCK
SVO FUNCTION IS:
CLAMP DELAY =4
TURN ON W/LEVEL 2=5
“SOFT TOUCH” =6
NO
YES
CLAMP(SV1) delay OFF
after SV0 turns OFF.
CLAMP (SV1) ON. Then
SV0 ON after DELAY.
Want to change? Push
the YES or NO button