SECTION D, PAGE 8
SOLUTION IN PRODUCTION
Enter the position of the welder
transformer TAP SWITCH. If your welder
does not have this switch, enter 1.
This line will remind the setup person that
the transformer TAP SWITCH should be
set to this number to match conditions
when this welding program was originally
set up and approved.
If your control has QC in the model
number, this line will also be used to
select the proper LEARN TABLE when
operating the control in CONSTANT
CURRENT mode.
Enter the desired force between
electrodes. See SETTING TIP FORCE
CALCULATOR SYSTEM in section B2
for information on this function.
If your control has QC in the model
number, it will wait for this selected TIP
FORCE to be reached before starting the
first weld heat sequence.
D3: START WELDING: After entering numbers on lines in this program,
press: and the display will show:
Set the TRANSFORMER TAP SWITCH to the #3 position.
Set the AIR PRESSURE REGULATOR to 35psi.
TIP FORCE 0000 LB
TRANSFORMER TAP # 3
TYPICAL TAP
SWITCH
PROGRAM 005 IS READY
Set TRANSF. TAP TO 3
Set PRES. REG. 35psi
STEP
ENTER