SECTION D, PAGE 9
D4: CHANGING HEAT% ON THE FLY: If you entered values for the
MODIFIED HEAT LIMITS (see C3), you can increase or decrease the WELDING
HEAT% “on the fly” without going into the welding program. This can be done
even if the keypad is in the LOCK position.
Each time you press the WELD HEAT% will increase 1%. You can do
this up until you have reached the limit set in section C3 (PROGRAM 978).
Each time you press the WELD HEAT% will decrease 1%. You can
do this up until you have reached the limit set in section C3 (PROGRAM 978).
If you have pushed these buttons to trim the WELD HEAT%, the original WELD
HEAT% that was set in this welding program will not be changed. But the next
line will show the current value of WELD HEAT% being used:
This confirms that the WELD HEAT% you are now using (MOD.WELD HEAT) is
87%. But the original WELD HEAT% is still 80%. In this way you will not lose the
original setting, but can trim it to match changes in material.
This MOD.WELD HEAT% will remain the value being used until either:
1. The WELD HEAT% value is changed. The MOD.WELD HEAT% will change to
the new WELD HEAT%.
2. You press when the ← is on the MOD.WELD HEAT line. This will
change the MOD.WELD HEAT% it to match the original WELD HEAT % value.
SQUEEZE TIME 15CY
WELD TIME 12 CY
WELD HEAT 80%
MOD.WELD HEAT 87%←