Questions and Answers

  • L
    laurabushAug 1, 2025
    Why is the battery symbol flashing on my UPM THM501?
    • G
      Gary GuerraAug 1, 2025
      If the battery symbol is flashing on your UPM Thermostat, replace the batteries with fresh alkaline batteries. It's also recommended to replace the batteries at least once a year, even if the battery symbol isn't flashing.
  • A
    Alexander DanielsAug 5, 2025
    How to fix a blank LCD screen on my UPM Thermostat?
    • R
      Ralph AndersonAug 5, 2025
      If the LCD screen on your UPM Thermostat is blank, try the following: * Ensure the batteries are correctly installed. * Verify the batteries are fresh and of the correct type. * Press the RESET (R) key on the back of the thermostat, located above the battery compartment.
  • K
    Kaylee ArmstrongAug 10, 2025
    What to do if the heat will not come on with my UPM Thermostat?
    • J
      Jennifer CampbellAug 10, 2025
      If the heat isn't turning on for your UPM Thermostat, make sure: the thermostat is set to HEAT or AUTO mode; the set temperature is higher than the current room temperature; and wait up to 5 minutes for the heat to turn on. After waiting 5 minutes, the heating should now be on.
  • S
    Sharon HernandezAug 14, 2025
    What to do if the air conditioning will not come on with my UPM THM501 Thermostat?
    • A
      Ashley CarrilloAug 14, 2025
      If the air conditioning isn't turning on for your UPM Thermostat, make sure that the thermostat is set to the COOL or AUTO mode. Also, check that the set temperature is lower than the current room temperature. You may need to wait up to 5 minutes for the air conditioning to activate. After waiting, the air conditioning should now be on.
  • S
    Samantha HayesAug 18, 2025
    Why does the heating system cycle often on my UPM THM501 Thermostat?
    • M
      Miss Brittany HensleyAug 18, 2025
      If your UPM Thermostat's heating system cycles too often, ensure you've selected a Cycle Rate that matches your heating system. The default is set at Cr-3 for gas or oil forced air systems. If it still cycles too often, try a slower cycle rate or disable the cycling.
  • N
    Nicholas CrawfordAug 22, 2025
    What to do if the air conditioning symbol is animated, but the AC won't turn on with my UPM Thermostat?
    • B
      Brian SmithAug 22, 2025
      If the air conditioning symbol is animated on your UPM Thermostat but the air conditioning isn't turning on, check if the air conditioning system's main switch is turned on. It may have been turned off. Also, wait several minutes for the air conditioning system to activate.
  • M
    Melissa LoweAug 27, 2025
    Why doesn't my UPM THM501 automatically change from HEAT to COOL in AUTO mode?
    • W
      William MaxwellAug 27, 2025
      The UPM Thermostat has a built-in 30-minute time delay to prevent undesirable change-over sequences from HEAT to COOL or COOL to HEAT when set to AUTO mode. You can manually override this delay by pressing the MODE button to select HEAT or COOL only.

Summary

LCD Display and Time Setup

Set Time and Day

Instructions for setting the current time and day on the thermostat.

Thermostat Programs

Fan Control and Operating Modes

Battery Replacement and Reset

Resetting the Thermostat

How to perform a soft reset or a hard reset on the thermostat.

Troubleshooting Guide

Troubleshooting: Blank LCD Screen

Solutions for when the thermostat's LCD screen is blank.

Troubleshooting: Flashing Battery Symbol

What to do when the battery symbol indicates low battery power.

Troubleshooting: No Heat Output

Solutions for when the heating system does not turn on.

Troubleshooting: Heat On Indicator, No Heat

Diagnosing why the heat indicator is active but no heat is produced.

Troubleshooting: No Air Conditioning

Solutions for when the air conditioning system does not turn on.

Troubleshooting: AC Indicator, No AC

Diagnosing why the AC indicator is active but no cooling is produced.

Thermostat Installation Process

Connecting Wires to Terminals

Instructions for connecting the system wires to the thermostat terminals.

UPM THM501 Specifications

General IconGeneral
BrandUPM
ModelTHM501
CategoryThermostat
LanguageEnglish

Related product manuals