TCC Solenoid overcurrent error
An over-current condition was detected on the torque converter clutch pressure
solenoid. A short circuit may be present in the solenoid circuit. The controller will
attempt to disable the TCC solenoid until the ignition is turned off.
EPC (PCS) Solenoid overcurrent error
An over-current condition was detected on the line pressure control solenoid. A
short circuit may be present in the solenoid circuit. The controller will attempt to
disable the solenoid with the over-current condition until the ignition is turned off.
Shift Solenoid A (SSA) undercurrent error
Current measured on the indicated shift solenoid was too low, indicating that the
solenoid circuit may be open.
Shift Solenoid B (SSB) undercurrent error
Current measured on the indicated shift solenoid was too low, indicating that the
solenoid circuit may be open.
Coast Clutch Solenoid undercurrent error
Current measured on the coast clutch solenoid was too low, indicating that the
solenoid circuit may be open. The controller will attempt to disable the coast
clutch solenoid until the ignition is turned off.
TCC Solenoid undercurrent error
Current measured on the torque converter clutch pressure solenoid was too low,
indicating that the solenoid circuit may be open. The controller will attempt to
disable the TCC solenoid until the ignition is turned off.
EPC (PCS) Solenoid undercurrent error
Current measured on the line pressure control solenoid was too low, indicating
that the solenoid circuit may be open.
Shift Solenoid A (SSA) circuit shorted
The indicated Shift Solenoid’s resistance measured too low during the power-on
solenoid check. Refer to the data display screen in the diagnostic menu to see
the measured solenoid resistance.