Owners Manual
US Water Systems Corporate Office
1209 Country Club Road
Indianapolis, IN 46234
info@uswatersystems.com
www.uswatersystems.com
1-800-608-8792
Visit us online at
www.uswatersystems.com
REVISION # 1.1
REVISION DATE June 27, 2017
US Water Systems 1” Fusion NLT Water
Softener

Other manuals for US Water Systems Fusion

Questions and Answers

  • S
    Sandra AllisonAug 15, 2025
    Why is my US Water Systems Water Filtration System using too much salt?
    • S
      Samantha CarneyAug 15, 2025
      Your US Water Systems Water Filtration System might be using too much salt due to an improper salt setting. Check the salt usage and salt setting to ensure they are correctly configured. Also, excessive water in the brine tank can cause this issue; refer to problem 7 for solutions related to excessive water in the brine tank.
  • W
    William KimAug 21, 2025
    How to fix loss of water pressure in my US Water Systems Water Filtration System?
    • M
      Matthew MooneyAug 21, 2025
      A loss of water pressure in your US Water Systems Water Filtration System can occur due to several reasons. Iron buildup in the line to the water conditioner can restrict flow, so clean the line. Similarly, iron buildup within the water conditioner itself can cause this issue; clean the control, add a mineral cleaner to the mineral bed, and increase the frequency of regeneration. Also, check if the inlet of the control is plugged due to foreign material dislodged from pipes during plumbing work; remove the piston and clean the control.
  • D
    David WatsonAug 25, 2025
    What to do if US Water Systems Water Filtration System softener fails to draw brine?
    • C
      Crystal GonzalezAug 25, 2025
      If your US Water Systems Water Filtration System softener isn't drawing brine, start by checking the drain line flow control to see if it's plugged and clean it if necessary. Also, inspect the injector for any blockages and clean it. A plugged injector screen can also prevent brine draw, so clean the screen. Ensure that the line pressure isn't too low; increase it to 20 P.S.I. An internal control leak may be the cause, so consider changing the seals, spacers, and piston assembly. Finally, verify that the service adapter cycled; check the drive motor and switches.
  • M
    Mrs. Heather LevyAug 27, 2025
    What causes a US Water Systems Water Filtration System to fail to regenerate?
    • L
      Linda SmithAug 27, 2025
      A US Water Systems Water Filtration System might fail to regenerate for a few reasons. First, check that the electrical service to the unit hasn't been interrupted; ensure permanent electrical service by checking the fuse, plug, pull chain, or switch. If the electrical supply is fine, the control itself might be defective and need replacement. Lastly, a power failure can prevent regeneration; reset the time of day on the unit.
  • B
    Breanna RobertsAug 30, 2025
    How to stop continuous drain flow in my US Water Systems Water Filtration System?
    • N
      nathan83Aug 30, 2025
      Continuous drain flow in your US Water Systems Water Filtration System may be due to the valve not programming correctly. Check the control program and positioning of the control. If it's not positioning properly, replace the power head assembly. Foreign material in the control can also cause this; remove the power head assembly, inspect the bore, remove any foreign material, and check the control in various regeneration positions. An internal control leak can also lead to continuous drain flow, so replace the seals and piston assembly.
  • A
    Alicia WilliamsSep 2, 2025
    What causes excessive water in the brine tank of my US Water Systems Water Filtration System?
    • M
      matthewalvarezSep 2, 2025
      Excessive water in the brine tank of your US Water Systems Water Filtration System can be caused by several issues. A plugged drain line flow control can be the culprit, so clean the flow control. Alternatively, a plugged injector system might be the cause, so clean the injector and screen. If the timer isn't cycling, consider replacing it. Foreign material in the brine valve or brine line flow control can also lead to this problem, so replace the brine valve seat and clean the valve, and clean the brine line flow control.
  • J
    John BairdSep 5, 2025
    Why does my US Water Systems Water Filtration System have iron in the conditioned water?
    • A
      Amanda PriceSep 5, 2025
      Iron in the conditioned water from your US Water Systems Water Filtration System is often due to a fouled mineral bed. Check the backwash, brine draw, and brine tank fill. You may need to increase the frequency of regeneration and the backwash.
  • M
    Mark CostaSep 8, 2025
    How to fix mineral loss through the drain line of my US Water Systems Water Filtration System?
    • R
      ronaldhaneySep 8, 2025
      Mineral loss through the drain line in your US Water Systems Water Filtration System can be attributed to a couple of reasons. Air in the water system might be the cause; ensure that the well system has a proper air eliminator control and check for a dry well condition. Another potential cause is an improperly sized drain line flow control; check for the proper drain rate.
  • M
    Mr. Joe PageSep 12, 2025
    What to do if my US Water Systems Water Filtration System control cycles continuously?
    • S
      Sandra EdwardsSep 12, 2025
      If the control of your US Water Systems Water Filtration System cycles continuously, it could be due to a misadjusted, broken, or shorted switch. Determine if the switch or timer is faulty and replace it, or replace the complete power head.
  • E
    epetersonNov 17, 2025
    What to do if my US Water Systems Water Filtration System has hard water?
    • S
      Scott RodriguezNov 17, 2025
      If you're experiencing hard water with your US Water Systems Water Filtration System, several factors could be the cause. First, ensure the bypass valve is closed. Also, check the brine tank and add salt, maintaining the salt level above the water level. A plugged injector screen can also cause hard water, so clean the injector screen. Insufficient water flowing into the brine tank can be another reason; check the brine tank fill time and clean the brine line flow control if it's plugged. If you have a hot water tank, repeated flushing might be required to address hot water tank hardness. A leak at the distributor tube can also lead to hard water; inspect the distributor tube for cracks and check the O-ring and tube. Finally, an internal valve leak could be the problem; consider replacing ...

Summary

Unpacking and Inspection

Safety Guide

General Safety Precautions

Comply with codes, handle tank carefully, use correct transformer, and use proper salt type.

Proper Installation

Installation Environment

Avoid freezing, direct sunlight, and ensure proper grounding and lead-free solder.

Installation Preparation

Tools and Materials Needed

Gather channel locks, screwdriver, Teflon tape, wrenches, and recommended piping materials.

Softener Installation Location

Electrical and Environmental Setup

Ensure grounded outlet access, protect from weather, and avoid direct sunlight.

Softener Tank Preparation

Control Valve Attachment

Lubricate O-rings, attach the control valve to the tank, and hand-tighten securely without tools.

Bypass Valve and Connector Installation

Install bypass valve and connectors, lubricating O-rings and securing with clips.

Integrated Bypass Valve Installation

Installation Instructions

Control Panel Button Configuration

Softener Programming Levels

Softener Programming Guide

Manual Regeneration Process

Water Softener Startup Procedure

Initial Water Flow and Backwash

Ensure bypass set, turn on water, flush air, and initiate manual regeneration for backwashing.

Rinsing and Refill Cycles

Advance to rinse, ensure clear water, allow refill, and add water to the brine tank.

Water Softener Maintenance

US Water Systems Fusion Specifications

General IconGeneral
BrandUS Water Systems
ModelFusion
CategoryWater Dispenser
LanguageEnglish

Related product manuals