3
Operating Instructions
Programming the Timer
1. Tosettheauto-OFFtime,presstheTimerbuttonuntiltheOfflightilluminates.
2. UsetheUpandDownbuttonstoadjustthetimersettinginhalf-hourincrementsupto10hoursandhour
incrementsupto24hours.
3. Tosettheauto-ONtime,presstheTimerbuttonuntiltheOnlightilluminates.
4. UsetheUpandDownbuttonstoadjustthetimersetting.
5. Waitvesecondsfortheunittoacceptthesetting.
Continuous Mode
PresstheCont.buttontoconstantlyrunthedehumidier.Thehumiditylevelcannotbemanuallysetwhentheunitis
operatingincontinuousmode.
Emptying the Water Tank
Whenthewatertankisfull,theFulllightilluminatesandthedisplayreads“P2.”Ifthedehumidierisrunning,the
compressorturnsOFF(thoughthefanmaycontinuetorun).
1. Gripthehandlesonthesidesofthewatertankandslowlypullthetankoutoftheunit.Donot
placethetankontheoorasitsunevenbottommaycauseittospill.
2. Emptythetankandcarefullyreplaceitintheunit.IftheunitisON,operationwillresumeoncethetankis
properlyreinstalled.
Continuous Drainage
Tocontinuouslydrainwaterfromtheunit,
1. ConrmtheunitispoweredOFF.
2. Removethecoverfromthedrainhoseoutlet.
3. Threadthefemaleendofagardenhose[orotherhose(
5
/16-inch-IDorgreater)withgardenhosethread,not
included]ontotheunit’sdrainhoseoutlet.Ensurethehoseissecurelyattachedtotheoutlet.
4. Directtheotherhoseendtoaoordrainorothersuitabledisposalarea.
5. TurntheunitON,thenselecttheoperationmodeandprogramsettingsasdesired.
Detachthedrainhoseandreplacetheoutletcoverwhenthecontinuousdrainagefunctionisnotinuse.
Auto-Shutoff
TheunitwillturnOFFwhenthewatertankreachescapacity.TheunitwillalsoturnOFFautomaticallywhentheset
humiditylevelisreached.Thefanmotormaycontinuetorunevenwhendehumidifyingfunctionhasceased.
Auto-Defrost
Whenfrostaccumulatesontheevaporatorcoils,thecompressorwillautomaticallyturnOFFandthefanwillcontinue
torununtiltheevaporatorcoilsdefrost.
Auto-Restart
Afterapowerinterruption,theunitwillrestartautomaticallyusingthepreviouslyprogrammedsettings.
Toprotecttheunit,thecompressorwillnotrestartuntilthreeminutesaftershuttingdown.
Comfort Mode
Whenoperatingincomfortmode,theunitautomaticallyadjuststhehumiditylevelaccordingtotheambient
temperaturetomaintainacomfortableenvironment.Theautomatedhumiditylevelsareshowninthechartbelow.
Whencomfortmodeisactive,thehumiditylevelcannotbemanuallyset.
Ambient Temperature Humidity Setting
<64.4°F 55%
64.4°Fto77°F 50%
>77°F 45%