SCUBAPRO AIR 2
Trouble Shooting Guide
Symptom Correction Tools Needed
Continuous slow leak from
downstream regulator
Readjust orifice or nyloc nut Replace seat, orifice, or spring Air 2 Spider Tool
Continuous slow leak from
downstream regulator
High IP – See first stage trouble shooting Pneumatic adjustment tool
or IP gauge
Inhalation effort is lower than
specification
Readjust orifice or nyloc nut Various