Installation instructions
Room air laundry dryer
One-family household
1064364-07
04/10/2022
1064364-07
1
Validity
The installation instructions apply to the model: 12014
Warnings
The appliance should be installed by qualified personnel only.
Each step must be carried out and checked in full in the order specified.
Check the appliance for visible damage. Do not use the appliance if it is damaged in any way.
Transport the appliance in an upright position only! Transporting it in any other position will result in damage to the
appliance! When carried carefully without being shaken, the appliance may be tilted a maximum of 90° to the left
(viewed from the front).
Do not connect this appliance
to a voltage source that is controlled by an external device such as a time switch, timer or device that regularly switches
the voltage to the outlet on and off (as in the case of a
Mittagssperre
or midday power shut-off),
or to a voltage source that is switched by a CoinSystem1, CoinSystem2, CardSystem1, CardSystem2 or VESTA cash-
ier system from V-ZUG Ltd.
Room size, room climate and ventilation
Keep all ventilation slits on the appliance clear and unobstructed. Otherwise an adequate supply of air is not guaran-
teed.
For the tumble drying operating mode: Ensure that the temperature of the room is between 5–35°C.
For the room air drying operating mode: Ensure that the temperature of the room is between 8–35°C.
The room temperature must be kept between the range of 15–25°C to ensure the economic running of the appliance.
For the tumble drying operating mode
Room size <10m² (<20m³) Room size 10-25m²(20-50m³)
Room must be ventilated: There
must be air inlet and outlet openings
to the adjacent room or to the out-
side, e.g. open window/door, ventil-
ation grille or slits in the door or
ventilation system.
Condensation may form on thermal
bridges! The room must therefore
be aired after running several con-
secutive drying programmes, e.g.
by opening a window or door to the
room.
For the room air drying operating mode
Room size ≤25m² (≤50m³)
Doors to and windows in the room
must be kept closed during the dry-
ing process.
If a room ≥25 m² (≥50 m
3
), the laun-
dry cannot be guaranteed to have
reached the desired level of dryness
when the programme ends.
Question and Answer IconNeed help?

Do you have a question about the V-ZUG V4000 DualDry and is the answer not in the manual?

V-ZUG V4000 DualDry Specifications

General IconGeneral
BrandV-ZUG
ModelV4000 DualDry
CategoryDryer
LanguageEnglish

Summary

General Safety Warnings

Installation and Handling Precautions

Ensures appliance is installed by qualified personnel, checked thoroughly, and handled safely.

Transport and Damage Checks

Mandates upright transport and checks for visible damage before use.

Electrical Connection Restrictions

Prohibits connection to external switching devices or specific cashier systems.

Niche Installation Requirements

Niche Variants and Specifications

Details dimensions and requirements for niche variants 'a', 'b', and 'c'.

Installation Plate Fastening

Floor Fastening (No Underfloor Heating)

Instructions for securing the installation plate using screws.

Floor Adhesion (With Underfloor Heating)

Method for adhering the installation plate using double-sided tape.

Electrical and Drain Connections

General Electrical Connection Safety

Emphasizes qualified personnel, proper earthing, and accessible switches.

Condensate Drain Connections

Drain Hose Length and Watertightness

Warns against lengthening the drain hose and making watertight connections.

Advanced Drain Connections and Levelling

Appliance Positioning and Levelling

Ensures the appliance stands level and stable on its feet.

Initial Operation and Function Test

Related product manuals