3.1 Dimension drawings
3.1.1 RFI footprint filters
Figure 11. 70CTC1100857 Rev. B enclosure size 4
# Reference # Reference
A
Wire 4x2.5 mm
2
B
Line connector; Minimum 5 mm
2
,
Maximum 16 (solid 25) mm
2
Stripping length 16 mm
Tightening torque 2 - 2.3 Nm
C
Maximum screw length for AC drive
mounting; M6x16
7128_00
61.5
15±2
57.5
100±5
70±1
10±1
40±1
30±1
320±15
128
100±1
30±1
14
313±0.8
378±1
378±1
10
43.5
10
395
Ø13
Ø7
C
A
B
70CTC1100857 Rev.B