8
4.3 Some uid is drawn but performance is slow / no adequate vacuum
(Note: A noticeable drop in the sound level should be apparent shortly after
depressing the lever. This indicates that proper vacuum is being developed).
1. Is the working pressure below the minimum of 5.5 bar (80 psi)? Check for
kinked or blocked hose, poor quality restrictive couplings or ttings and
replace if necessary.
2. Are seals damaged? Check seals of canister head and safety valve for pro-
per condition and replace if necessary.
3. Is the silencer locked? Clean or replace silencer (Attention: do not attempt
to operate without silencer in place!).
4. Is the drain valve open? Close the valve.
5. Is the rubber tting or hose damaged allowing air to enter? Replace with the
new parts if necessary.
5. Maintenance
5.1 General
Fig. 9 Remove the silencer cap (a) and clean the silencer sleeve (b) regularly
with air.
Always keep the unit clean and replace seals if necessary. There is no further
special servicing necessary.
5.2 Spare parts
See spare part list or ask your local dealer
5.3 Waste disposal
Brake uid contaminates the environment. Hand over used brake uid to an
expert for a proper disposal. Always follow your local laws and regulations.
6. Appendix
6.1 Technical data
Working pressure: 5.5 - 12 bar (80 -175 psi)
Vacuum generated: approx. - 0.85 bar
Thread: ¼”
Capacity: 1.5 liter (type Classic) and 2.5 liter (type Drainman)
6.2 Supplier / distributor
See last page or delivery slip
6.3 Warranty
As per our current warranty regulations