3. Close the tank isolation valve and then
remove the priming port plug on the top of
the pump casing.
4. Slowly open the tank isolation valve
allowing water to fill the suction line and
pump casing. This will expel the air as the
water fills the suction line and pump casing.
5. Once all air is expelled a steady stream of
water will trickle out.
6. Close the isolation valve and replace the
priming port plug. The isolation valve
must be re-opened prior to operation.
Your pump is now primed. Before pump
operation ensure there is sufficient water
inside the tank.