55Installation Instructions VRC 630 0020095108_00
Operating the controller 7
7.2.6 Menu 7: Changing names
During commissioning, the controller displays only the
factory-set names for the heating circuits and the DHW
cylinder.
In Menu
7, you can change the factory-specified
names of the heating circuits to provide the owner with
a better overview of the installation.
Name
7
change
HK1
:
HK1
HK2
:
HK2
HK3 HK3
> Select
Settable
parameters
Description Setting range
Factory set-
ting
HK1 Name of the heating circuit max. 10-digit
A ... Z, 0 ... 9
Space
HK1
HK2 ... HK15
Table 7.7 Changing names
i
Changed names are automatically adopted
and displayed in the respective menus.
i
You can only ever change 1 character at a
time.
If you want to change the full name, you must change
each character individually and possibly add cha-
racters.
If you want to delete characters at the end of the
name, you must overwrite the characters with
spaces.
The controller saves the new name and displays it in all
menus henceforth.
After an extended period without any operations, the
display automatically reverts to the basic display.
The end result might look like this:
Name
7
change
HK1
:
Floor1
HK2
:
Bathroom
HK3 HK3
> Select
>
>

Table of Contents

Questions and Answers:

Vaillant VRC 630 Specifications

General IconGeneral
Power SupplyMains powered
Protection ClassIP20
CompatibilityVaillant heating systems
DisplayLCD
CommunicationeBUS
Operating Voltage230 V
Ambient Temperature0 to 40 °C
TypeWeather Compensated Controller
FunctionsWeather-compensated control, time programming

Related product manuals