8 Installation and maintenance instructions ecoFIT sustain 0020277262_02
VU 156/6-3 OV (H-GB) VU 186/6-3 OV (H-GB) VU 306/6-3 OV (H-GB)
Effective output range (P)
at 80/60 °C
4.5 to 15.2 kW 5.0 to 18.3 kW 7.1 to 30.5 kW
Domestic hot water heat
output (P)
4.4 to 18.0 kW 4.9 to 25.2 kW 7.0 to 35.0 kW
Maximum heat input
heating (Q max.)
15.3 kW 18.4 kW 30.6 kW
Minimum heat input heat-
ing (Q min.)
4.5 kW 5.0 kW 7.1 kW
Maximum heat input hot
water (Q max.)
18.4 kW 25.7 kW 35.7 kW
Minimum heat input hot
water (Q min.)
4.5 kW 5.0 kW 7.1 kW
Technical data Heating
VU 156/6-3 OV (H-GB) VU 186/6-3 OV (H-GB) VU 306/6-3 OV (H-GB)
Max. flow temperature ad-
justment range (default
setting: 75 °C)
10 to 80 10 to 80 10 to 80
Maximum permissible
pressure
0.3 MPa
(3.0 bar)
0.3 MPa
(3.0 bar)
0.3 MPa
(3.0 bar)
Nominal water flow
(ΔT = 20 K)
655 l/h 788 l/h 1,313 l/h
Nominal water flow
(ΔT = 30 K)
436 l/h 525 l/h 876 l/h
Approximate value for the
condensate volume (pH
value between 3.5 and 4.0)
at 50/30 °C
1.53 l/h 1.84 l/h 3.06 l/h
Technical data Electrics
VU 156/6-3 OV (H-GB) VU 186/6-3 OV (H-GB) VU 306/6-3 OV (H-GB)
Electrical connection
230 V / 50 Hz 230 V / 50 Hz 230 V / 50 Hz
Built-in fuse (slow-blow)
T2/2A, 250V T2/2A, 250V T2/2A, 250V
Max. electrical power con-
sumption
29 W 35 W 44 W
Standby electrical power
consumption
2 W 2 W 2 W
IP rating
IPX4D IPX4D IPX4D