High voltage warning about roof lining and electrocution risk.
Critical safety step to disconnect power before any work.
Table specifying required service clearances for unit access and operation.
Safe lifting procedures and precautions for the unit.
Instructions for mounting the unit on a roof curb.
Critical warning against drilling into the unit's roof due to high voltage wiring.
Guidelines for installing DX coils and associated piping for split systems.
Warning about high voltage wiring in the roof lining.
Warning about locking disconnect switches for safety.
Important instruction to read manuals before connecting power.
Requirement to follow electrical codes for all wiring.
Danger warning about high voltage electrical input.
Important information regarding defrost cycles for ASHP units.
Importance of field calibration for the airflow monitoring device.
Explanation of frost control options to prevent wheel frosting.
Location and function of the VFD compressor.
Overview of the microprocessor controller's capabilities and features.
Schematic of the Packaged DX cooling system with hot gas reheat and bypass.
Schematic of the Air-Source Heat Pump system with hot gas reheat.
Operation of the thermostatic expansion valve (TVX).
Function of the four-way reversing valve.
Operation of EXV or TXV for refrigerant flow control.
Danger warning about electric shock hazards during start-up.
Warning about factory testing and initial checks for correct operation.
Pre-start-up procedure for energizing the unit for 24 hours.
Checklist to be completed for proper unit start-up.
Checklist items to perform before unit start-up.
Electrical checks to perform during pre-start-up.
Pre-start-up checks related to compressors.
Step-by-step procedure for unit start-up.
Explanation and formula for calculating voltage imbalance.
Table to record amperage draw for various motors.
Table to record compressor operating conditions.
Table for recording compressor electrical data.
Superheat specifications for specific models.
Subcooling specifications for specific models.
Superheat specifications for VX/VXE-352 models.
Subcooling specifications for VX/VXE-352 models.
Expected discharge pressure range.
Expected suction line pressure range.
Table for recording compressor electrical data.
Superheat and subcooling ranges for cooling mode.
Expected discharge pressure range.
Expected suction line pressure range.
Superheat and subcooling ranges for heating mode.
Steps for field calibrating the airflow monitoring device.
How the microprocessor controls frost prevention.
Safety warning for maintenance on the energy wheel.
Troubleshooting step for when the energy wheel does not turn.
Troubleshooting step for intermittent energy wheel operation.
Alarms and indicators for the microprocessor controller.
LED indicators and fault conditions for the phase monitor.
Alarm conditions and displays for Variable Frequency Drives.
Information on the digital scroll compressor controller and its alarms.
Chart of fault codes for the digital scroll compressor controller.
Troubleshooting steps for blower failure to operate.
Troubleshooting for motor starter issues.
Troubleshooting for motor over-amperage conditions.
Troubleshooting steps for low airflow conditions.
Troubleshooting steps for high airflow conditions.
Troubleshooting steps for excessive noise or vibration.
Troubleshooting for compressor failure to start.
Troubleshooting for compressor cutout due to high pressure.
Troubleshooting for excessive evaporator coil load.
Troubleshooting for low discharge pressure.
Troubleshooting for compressor cutting out due to low pressure.
Troubleshooting for high pressure switch cutout.
Troubleshooting for unloaded digital scroll compressors.
Troubleshooting for low pressure switch cutout.
Troubleshooting for compressor thermal overload cutout.
Troubleshooting for high suction pressure.
Troubleshooting for compressor humming but not starting.
Troubleshooting for high discharge pressure.
Troubleshooting for noisy or vibrating compressors.
Troubleshooting for low suction pressure.
Warning about biological hazards and need for qualified personnel.
Verification of power supply and voltage readings.
Detailed compressor performance data recording.
Comprehensive operational data for compressors in different modes.
Verification of DDC controller wiring, inputs, outputs, and configuration.
Testing of DDC controller modes like Heating, Cooling, Economizer.
Table for documenting DDC parameter settings.