HEATING SYSTEMS
THERMO PLUS
230/300/350
Rev. 05/2018
Id.No. 11121148B
NOTE: Subject to modification. In multilingual
versions the German language is binding. The
latest version of this document is provided for
download on www.valeo-thermalbus.com.
Operating and
service instructions

Other manuals for Valeo thermo plus 300

Questions and Answers

  • K
    Kevin TranAug 8, 2025
    What to do if Valeo Heater has no fuel delivery?
    • H
      heidi10Aug 9, 2025
      If there's no fuel delivery to the Valeo Heater, check the fuel delivery to the heater. Possible causes include an empty fuel tank; bent, closed, clogged, or leaking lines; paraffin deposits or frozen water in fuel lines; a closed venting opening in the tank; mixed-up fuel lines; a contaminated fuel filter or screen in the pump; a defective fuel pump or coupling; or fuel lines that aren't vacuum-tight.
  • D
    David DiazAug 18, 2025
    Why Valeo Heater CO value cannot be adjusted?
    • P
      Pamela RodriguezAug 18, 2025
      If the CO value of the Valeo Heater cannot be adjusted to the nominal value, and there's irregular combustion, adjust the CO value to the nominal value. Possible causes include air bubbles in the fuel supply line (leaking fuel supply line), a contaminated or leaking fuel filter, a leaking fuel integration (suction lift, low pressure in tank), a defective fuel pump, a contaminated screen in the fuel pump, an ineffective O-ring seal on the fuel pump, a defective atomizer nozzle, throttled or closed combustion air and exhaust lines, a burner motor speed that is too low, or a defective coupling.
  • S
    Scott JacksonAug 28, 2025
    What to do if the circulating pump of Valeo Aquavent 6000S does not operate?
    • F
      fkennedyAug 28, 2025
      If the circulating pump of your Valeo Aquavent 6000S or 6000SC doesn't operate, it might be due to an activated error mode. In case of malfunctions, the motor is switched off via the error mode. Reactivate the circulating pump motor by disconnecting the power supply for more than 2 minutes. After reconnecting the power supply, the motor will perform a soft start.

Summary

General Information

Safety and Operation

Prohibited Operating Conditions

Heater must not be operated at filling stations or near flammable materials/vapors.

Operational Restrictions and Requirements

Do not exceed 110°C, use adequate antifreeze, use approved fuel, and operate monthly.

Liability Claims

Liability is refused if installation/repair instructions or genuine parts are not followed.

Heater Operation and Controls

Pre-selection Timer Overview

Explains the function and components of the pre-selection timer for programming start times.

Setting Time and Day

Instructions for setting the current time, day of the week, and 12/24h format.

Programming Operation Duration

Guide to setting how long the heater will operate once started.

Programming Heater Starting Time

How to set specific start times for the heater up to 7 days in advance.

Activating and Deactivating Pre-selection

Steps to activate a programmed start time and deactivate it.

Instant Heating Function

How to activate continuous operation immediately.

Malfunction and Troubleshooting

Initial Fault Checks

Basic checks for fuel supply, fuses, connections, and air ways when a fault occurs.

Fault Lock-Out Conditions

Explains when the heater enters fault lock-out mode and common causes.

Resetting After Fault Lock-Out

Procedures to reset the heater after it enters fault lock-out.

Interpreting Flash Codes

How to understand error indications via operating light or display.

Flash Code Reference Table

A table listing malfunction descriptions corresponding to long pulse counts.

Valeo thermo plus 300 Specifications

General IconGeneral
Voltage230V
Frequency50 Hz
TypeStorage water heater
ThermostatAdjustable
ProtectionOverheating protection, safety valve