EasyManua.ls Logo

Valore SUMMIT VSU-E36CS - Ductless Recirculating Installation; Recirculating Kit and Filter Setup

Default Icon
21 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed.
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust
IURPFRRNLQJDUHGUDZQDQG¿OWHUHGE\DVHWRIRSWLRQDOFKDUFRDO¿OWHUV7KHDLULVWKHQSXUL¿HGDQGUH
circulated back within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct
ZRUNLISRVVLEOH7KHKRRGLVPRVWHIIHFWLYHDQGHI¿FLHQWDVDQH[KDXVWKRRG2QO\ZKHQWKHH[KDXVWRSWLRQ
is not possible should you recourse to converting the hood into a recirculating hood.
:KHQFRQYHUWHGWREHDUHFLUFXODWLQJKRRGDVHWRIFKDUFRDO¿OWHUVDUHUHTXLUHGRQWRSRILWVVWDQGDUG0HWDO
Filter set. Order according to its Part number below. The standard Metal Filters are intended to capture
UHVLGXHIURPFRRNLQJDQGWKHRSWLRQDOFKDUFRDO¿OWHUVKHOSWRSXULI\IXPHVH[KDXVWHGIURPFRRNLQJIRUUH
circulation.
RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED)
.LWLQFOXGHVFKDUFRDO¿OWHUVDQGDLUGLYHUWHUSODWH
Hood Model Part No. Filters & Brackets in Pkg.
VSU-ExxCS models VRC-01SU 2
VPL models VRC-00PL 2
1. Purchase recirculating kit per the part number above
 6HFXUHDLUGLYHUWHUSODWHWRZDOOEHORZGXFWFRYHUEUDFNHW),*%5XQ´
ducting from top of hood and secure to air diverter plate.
 5HPRYHPHWDOPHVK¿OWHUVIURPKRRG6HFXUHWKHFKDUFRDO¿OWHUEUDNHWRQWRWKH
LQVLGHRIWKHKRRGEHKLQGPHVK¿OWHUVZLWK0[VFUHZV&OLSFKDUFRDO
¿OWHUVRQWRHDFKFKDUFRDO¿OWHUEUDFNHW),*&
5H,QVWDOOPHWDOPHVK¿OWHUV
 &KDUFRDO¿OWHUVPXVWEHUHSODFHGDIWHUHYHU\KRXUVRIXVHRU
approximately every 3 to 4 months based on the average of 1 - 2 hrs. of
GDLO\FRRNLQJWLPH
Charcoal Filter Replacements
Hood Model Part No. Qty to Order
VSU-ExxCS and VPL V0F-C002 2
'2127:$6+&+$5&2$/),/7(56&KDUFRDO¿OWHUVPD\QHHG
to be changed more often depending on cooking habits.
Charcoal Filter Dimensions:
9in x 6-3/8in
228mm x 162mm
Installation – Ductless Recirculating
D
E
Install charcoal filter (plastic side exposed)
into charcoal filter bracket. Insert tab
cut-out side D of charcoal filter into bracket
first. Lock charcoal filter into place by
pushing down on side E with locking tabs.
front of the hood
back of the hood
FIG. C
FIG. B