32
DATI TECNICI
E1
TECHNICAL DATA
DESCRIZIONE NG LPG DESCRIPTION
N.6-7 = Ø ugello bruciatore 3.4 x 1 2.2 x 1 N.6-7 = Ø burner nozzle
H = Regolazione aria Primaria
( vedi figura )
H - 9/32 in
H - 7 mm
H - 5/16 in
H - 8 mm
H = Primary air adjustment
( see figure )
DATI TECNICI
E2
TECHNICAL DATA
DESCRIZIONE NG LPG DESCRIPTION
N.6-7 = Ø ugello bruciatore 2.6 x 2 1.7 x 2 N.6-7 = Ø burner nozzle
H = Regolazione aria Primaria
( vedi figura )
H - 9/32 in
H - 7 mm
H - 5/16 in
H - 8 mm
H = Primary air adjustment
( see figure )
DATI TECNICI
E3
TECHNICAL DATA
DESCRIZIONE NG LPG DESCRIPTION
N.6-7 = Ø ugello bruciatore 2.6 x 3 1.7 x 3 N.6-7 = Ø burner nozzle
H = Regolazione aria Primaria
( vedi figura )
H - 5/16 in
H - 8 mm
H - 5/16 in
H - 8 mm
H = Primary air adjustment
( see figure )
ATTENZIONE:
APPARECCHIATURA GIÀ TARATA
DAL COSTRUTTORE.
Previo malfunzionamento contattare il costrut-
tore per eseguire la regolazione della pressione
in uscita.
CAUTION:
EQUIPMENT ALREADY CALIBRATED
BY THE MANUFACTURER.
If malfunctions are detected, contact the
manufacturer to adjust outlet pressure.
Tab.7.8