EasyManua.ls Logo

Vamparossa E Series - User Manual

Default Icon
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
MANUALE INSTALLAZIONE
INSTALLATION MANUAL
BRUCIATORE A GAS • GAS BURNER
E
LINEA PROFESSIONALE
COMMERCIAL SERIES
Question and Answer IconNeed help?

Do you have a question about the Vamparossa E Series and is the answer not in the manual?

Summary

General Information

Symbols Used in the Manual

Explains symbols like CAUTION, WARNING, N.B., and QUALIFIED TECHNICIAN for safe operation.

Terminology

Defines key terms such as Equipment, Operator, Qualified technician, Exposed person, Danger zone, and PPE.

Safety Standards

Product Presentation and Components

Components of Vers. E-1 Horizontal

Lists and illustrates the components specific to the E-1 horizontal burner model.

Components of Vers. E-2 Horizontal

Lists and illustrates the components specific to the E-2 horizontal burner model.

Components of Vers. E-3 Horizontal

Lists and illustrates the components specific to the E-3 horizontal burner model.

Electrical Components

Illustrates the electrical components and wiring of the burner unit and transformer.

Components Description

Provides a detailed list of all components with reference numbers and their descriptions.

Product Information (Warnings, Improper Use, Identification Data)

Covers warnings, prohibited uses, and identification data for the equipment.

Technical Data

Technical Data Tables (E-1, E-2, E-3)

Details technical specifications for E-1, E-2, and E-3 models, including gas types, pressures, and consumption.

Environmental Conditions (Lighting, Noise, Vibrations, EMC)

Provides guidance on lighting, noise emissions, vibrations, and electromagnetic compatibility.

Machine Safety Devices and Protections

Data Plate Locations and Identification

Explains that data plates must remain legible and visible for identification and maintenance.

Lifting, Transport, and Storage

Transport and Handling Procedures

Details requirements for qualified personnel and safe handling, transport, and storage practices.

Installation Procedures

General Installation Requirements

Outlines requirements for qualified personnel, site preparation, and utility connections.

Electrical Connection Procedures

Specifies safety procedures and checks for connecting the equipment to the electrical mains.

Electrical Diagram & Site Requirements

Provides the electrical circuit diagram and requirements for the installation site and ventilation.

Flue System Installation

Details requirements for flue installation, including different types and sensor placement.

Gas Connection & Pressure Checks

Covers gas connection standards, materials, volumetric method, and connection pressure verification.

Gas Conversion & Nozzle Replacement

Explains the process for converting gas types and replacing main burner nozzles.

Outlet Pressure Adjustment

Details how to adjust maximum and minimum outlet pressure for proper flame control.

Thermostat Bulb Assembly & Inspection

Provides instructions for assembling and inspecting the thermostat bulb for future replacement.

Product Dimensions

Dimensions E-1 Horizontal Burner

Provides detailed physical dimensions for the E-1 horizontal burner model.

Dimensions E-2 Horizontal Burner

Provides detailed physical dimensions for the E-2 horizontal burner model.

Dimensions E-3 Horizontal Burner

Provides detailed physical dimensions for the E-3 horizontal burner model.

Dimensions Electrical Components

Shows the physical dimensions for the transformer and burner electrical units.

Assembly Types

Horizontal Burner Assembly Configurations

Illustrates different assembly configurations for horizontal burners based on oven diameter.

Vertical Burner Assembly Configurations

Illustrates assembly configurations for vertical burners.

Sensor and Electrode Installation

Temperature Sensor Assembly

Details the correct installation procedure for the temperature sensor within the oven.

Flue Gas Sensor Assembly

Shows the correct procedure for assembling the flue gas sensor.

Burner Electrode Positioning

Details the correct positioning and clearance for flame ignition and detection electrodes.

Electrical and Gas Valve Connections

Electrode Cable Connections

Illustrates the correct connection of flame ignition and detection electrode cables.

Gas Valve Positioning & Connections

Emphasizes correct vertical positioning of the gas valve and shows related connections.

Electrical Connections Overview

Provides comprehensive wiring diagrams for the burner unit and gas valve board.

Fuse Positions

Indicates the location and rating of fuses within the control and transformer units.

Operation and Maintenance Records

Initial Operation Test Report

Provides a template for documenting the initial start-up and testing of the burner.

Periodic Inspection Log

A log to record periodic inspections and maintenance performed by installers or technicians.

Vamparossa E Series Specifications

General IconGeneral
BrandVamparossa
ModelE Series
CategoryBurner
LanguageEnglish