The user can wear the IPAW6-10 in one of two ways:
l IPAW6-10 can be worn as a wrist watch (by inserting the wrist band into the two slits of the
appropriate ring holder).
l IPAW6-10 can be worn as a pendant by removing the wrist ring holder and replacing it with the
pendant ring holder.
Enrol a IPAW6-10 personal alarm button
To enrol the IPAW6-10 and assign it to User(n):
1. Select USERS > EDIT > USER(n) > RF FOB > ENABLED.
The keypad displays the ADD screen with a flashing ENROL DEVICE message.
2. On the IPAW6-10, press and hold the button.
The LED lights up for 1.5 seconds.
Disable a IPAW6-10 personal alarm button
To disable the IPAW6-10:
Select USERS > EDIT > USER(n) > RF FOB>DISABLED.
A message appears on-screen saying UPDATED.
16.9.2.4 IRCW6-11 remote control
The IRCW6-11 4-button Remote is a device that allows a user to remotely operate the SPC system.
The device supports ARM, STAY, and DISARM functionality, as well as the operation of defined
outputs and an SOS feature.
1 Arm
2 Stay
3 Disarm
4 Additional Function
5 Panic/SOS
6 LED
SPC4xxx/5xxx/6xxx Installation & Configuration Manual Engineer programming via the keypad
© Vanderbilt 2018 144 A6V10276959-d