Motor sprocket
Belt speed control knob
Fuse holder
Power cord
Belt speed control
Gear Motor
X-Series conveyor control assembly.
Model# XCB-DB-XXX
(XXX = 120 or 240 volt)
Caution:
With the control assembly removed there are
open wires and electrical connections.
Severe shock can occur if caution is not taken.
Chain Guard
To remove the chain guard:
Unfasten the two black sheet metal
screws at the top. Be sure to replace
the guard after adjustment is made.
In order to adjust the chain tension or remove the control assembly, the chain guard must first be removed.
Control assembly
mounting screws.
Control assembly
mounting screw
Drive Chain Adjustment
To adjust the drive chain, loosen the (3) control assembly mounting screws. Adjust any slack out of
conveyor chain and retighten screws.
Caution! Do not over tighten chain, damage to bearings may occur.
Maintenance
Electrical Electrical connections will loosen in time from heating and cooling. Every three (3) months the power should be turned
off at the external disconnect, or unplugged, and all the points of connection should be inspected and tightened.
Lint Buildup As with your clothes dryer at home lint will build up where ever air is flowing over garments.
Every six months
-The top cover should be removed to clean around the heater and any other visible debris buildup.
Every 2-3 months
-The optional exhaust blower, located on the rear of the machine, should be cleaned. To open the back panel
of the exhaust blower, remove the (14) black #8 machine screws for access to the blower.
Motor Chain Chains can loosen in time and should be inspected, adjusted, and lubricated when necessary. The motor chain is locat-
ed in the rear of the conveyor behind the Chain Guard.
Connections
Caution! Power must be turned off at the external disconnect, or the machine unplugged,
before entering any part of this machine. A qualified electrician should perform any internal
testing requiring power on!
DO NOT RUN YOUR CONVEYOR
WITHOUT THE CHAIN GUARD IN
PLACE.
8