Vaughn TOP PERFORMER PLUS - Installation Guidelines and Procedures; Heater Inspection and Content Verification; Proper Heater Location Selection

Default Icon
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2
INSTALLATION GUIDELINES
A. INSPECTING AND PREPARING THE HEATER
Remove the cardboard box, which comes packaged with the
heater. It should contain the following: Thermostat, T&P valve
and “T” (no “T” for model S70DTPP), insulation, lid and screws.
B. LOCATION
CAUTION: All tanks will eventually leak at some
unpredictable time.
Do not place the heater where there is a risk of property damage
in the event of a leak.
Place the heater on a solid foundation in a clean, dry location
nearest the boiler.
The heater should be protected from freezing and water lines
should be insulated to reduce energy and water waste.
Leave sufficient headroom to service the heat exchanger and
electrical controls.
Do not install in an area where flammable liquids or combustible
vapors are present.
CAUTION: The heater’s outer jacket is plastic and can melt.
Do not install in close proximity to wood burning stove or other
high temperature apparatus.
NOTE: If Heater is Placed on Blocks To Raise It From the Floor,
Be Sure to Support The Entire Bottom With At Least ¾ "
Plywood On The Top Of The Blocks.