VEC050D
VEC054D
VEC056D VEC051D
VEC049D
Power Inverter Model
*
VEC053D
.
Maximum Continuous Power 1000 watts 1500 watts 2000 watts 2500 watts 3000 watts
Surge Capacity (Peak Power) 2000 watts 3000 watts 4000 watts 5000 watts 6000 watts
Rated Input Voltage 12.8 - 13.2 volts 12.8 - 13.2 volts 12.8 - 13.2 volts 12.8 - 13.2 volts 12.8 - 13.2 volts
Output Voltage Range 105 - 125 volts 105 - 125 volts 105 - 125 volts 105 - 125 volts 105 - 125 volts
Output Frequency 58 - 62 Hz 58 - 62 Hz 58 - 62 Hz 58 - 62 Hz 58 - 62 Hz
Output Voltage 110/120VAC 60 Hz 110/120VAC 60 Hz 110/120VAC 60 Hz 110/120VAC 60 Hz 110/120VAC 60 Hz
Maximum Efficiency 87% 87% 87% 87% 87%
Full Load Efficiency 82% 82% 82% 82% 82%
No Load Current Draw <0.5 amp <0.6 amp <0.8 amp <1.0 amp <1.0 amp
Over Voltage Shutdown 15.5 ± 0.5 volts DC 15.5 ± 0.5 volts DC 15.5 ± 0.5 volts DC 15.5 ± 0.5 volts DC 15.5 ± 0.5 volts DC
Low Voltage Alarm 10.5 ± 0.3 volts DC 10.5 ± 0.3 volts DC 10.5 ± 0.3 volts DC 10.5 ± 0.3 volts DC 10.5 ± 0.3 volts DC
Low Voltage Shutdown 10.0 ± 0.3 volts DC 10.0 ± 0.3 volts DC 10.0 ± 0.3 volts DC 10.0 ± 0.3 volts DC 10.0 ± 0.3 volts DC
Thermal Shutdown Auto Reset YES YES YES YES YES
North American Standard Outlets 2 3 3 4 4
ANL Fuse Rating for Direct Hardwire 200 300 500 500 500
Proper Cable Gauge (AWG) @ 6 FT. #3 #2 1/0 2/0 2/0
Proper Cable Gauge (AWG) @ 10 FT. #1 2/0 3/0 3/0 250 mcm
*For lengths greater than 10 FT., contact Vector's Technical Support, toll-free, at (866) 584-5504
1. These models feature multiple U ground 120 volt AC outlets
2. All of these inverters meet North American Standard Requirements.
3. All units feature Siemens Mosfet power transistors.
1200 watts
2400 watts
12.8 - 13.2 volts
105 - 125 volts
58 - 62 Hz
110/120VAC 60 Hz
87%
82%
<0.6 amp
15.5 ± 0.5 volts DC
10.5 ± 0.3 volts DC
10.0 ± volts DC
YES
2
250
#3
1/0
VEC049D
VEC050D
VEC051D
VEC053D
VEC054D
VEC056D
USER’S MANUAL
& WARRANTY INFORMATION
IMPORTANT SAFETY INFORMATION, SAVE THESE INSTRUCTIONS
TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND
THIS INSTRUCTIONAL MANUAL. THIS MANUAL CONTAINS IMPORTANT
INFORMATION REGARDING THE OPERATION AND WARRANTY OF THIS
PRODUCT. PLEASE RETAIN FOR FUTURE REFERENCE.
www.vectormfg.com
4140 S.W. 30th Ave., Ft. Lauderdale, FL 33312
Toll Free: (866) 584-5504
VEC049D VEC053D
VEC050D VEC054D
VEC056D
VEC051D
MAXX SST
Compact Power Inverters
Converts 12 Volt DC to 120 Volt AC
Advanced MOSFET Technology
SPECIFICATIONS
VEC049_thru_56D_Manual_092205 10/21/05 11:50 AM Page 16

Questions and Answers

  • R
    Robert SmithAug 10, 2025
    What to do if my Vector Inverter has no AC output and the red LED is lit?
    • R
      rushtinaAug 11, 2025
      If your Vector Inverter has no AC output and the red LED is lit, it could be due to two reasons. First, the DC input might be below 10 volts, in which case you should recharge or replace the battery. Second, there might be an excessive appliance load causing a thermal shutdown. If this is the case, turn the unit off, reduce the load, wait for the inverter to cool down, and then turn it on again.
  • L
    Laura FinleyAug 16, 2025
    Why does the low battery alarm sound continuously on my Vector Inverter?
    • M
      Marcus ShawAug 16, 2025
      A continuous low battery alarm on your Vector Inverter typically indicates either low battery voltage or a bad connection/wiring. To resolve this, try recharging the battery, removing the load from the inverter while recharging. Also, ensure that you tighten all DC connections.
  • D
    Dr. Lisa White MDAug 22, 2025
    How to reduce television interference from my Vector MAXX SST VEC049D Inverter?
    • C
      Christopher FlynnAug 22, 2025
      To minimize television interference from your Vector Inverter: * Position the inverter as far as possible from the television, antenna, and antenna cables, using an extension cable if needed. * Adjust the orientation of the inverter, antenna cables, and TV power cord. * Ensure the antenna provides an adequate signal and uses high-quality, shielded antenna cable. * Avoid operating high-power appliances or tools while using the TV. * Make sure the inverter’s case is properly grounded.
  • A
    Alejandro HubbardAug 28, 2025
    How to stop buzzing sound in audio systems caused by Vector MAXX SST VEC049D Inverter?
    • H
      Hannah ChanAug 29, 2025
      If you're experiencing a buzzing sound in your audio system when using a Vector Inverter, it's likely because the power supply in your electronic device isn't adequately filtering the modified sine wave produced by the inverter. To resolve this, use a higher quality sound system that incorporates a higher quality power amplified supply.
  • J
    janetmartinezSep 3, 2025
    What to do if my Vector MAXX SST VEC049D Inverter has no AC output and the green LED is not lit?
    • K
      Karla MitchellSep 3, 2025
      If your Vector Inverter has no AC output and the green LED is not lit, the fuse(s) might be open. Check the DC input fuse(s) in the vehicle and replace the fuse with one of the same type and rating if necessary.