SI21 Solar Pump VFD Manual
16
Chapter 5 Parameters List
This chapter just provides function parameter table. Specifications refer to SI21 technical manual.
Environment setting
Parameter
(address)
Function
Description
Range of settings and definition
Factory
default
(setting range)
Notes
F00.03(0x0003
)
Initialization
V/F SVC
Set the VFD initialization method.
0: Not initialized
11: Select the set value according to the
purpose to carry out the parameters (excluding
the motor parameters)
22: All parameters are initialized
33: Clear the fault record
0
(033)
F00.04(0x0004
)
Keyboard
parameter copy
V/F SVC
0: No function
11: Upload parameters to the keyboard
22: Download parameters to the VFD
0
(09999)
F00.05(0x0005
)
User password
V/F SVC
Used to set the user password.
0
(065355)
Basic parameters
Parameter
(address)
Function
Description
Range of settings and definition
Factory
default
(setting range)
Notes
F01.00(0x0100
)
Motor 1
control mode
V/F SVC
The way the motor is controlled.
0: AM-VF; VF control
1: AM-SVC; Open loop vector control, current
closed loop control
0
(01)
S/T2
models
only
support
VF
control
F01.01(0x0101
)
Run command
channel
V/F SVC
Used to select the channel that the drive
accepts the run and stop commands and the
direction of travel.
0: Keyboard control (external keyboard
priority)
1: Terminal control
2: RS485 communication control
3: Reserved
0
(03)
F01.02(0x0102
)
Frequency
reference
source channel
V/F SVC
The frequency converter sets the given source
of the frequency.
0
(011)